Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I needed a service manual as the display on my oscilloscope was very dim. I thought I'd give owner-manuals.com a try, as they advertised a huge number of manuals. Sure enough they had one listed. I bought it hoping it would be useful... actually, I bought it hoping it would be readable! I've had manuals from online sources in the past, and been very disappointed. Not this time! An excellent manual, complete, and very readable. Using it I fixed my 'scope, and as such the manual was an investment that paid off manyfold. Do I have any complaints? One very minor one - The circuit diagrams could have been scanned at a higher resolution, as some of the details were a little difficult to make out - not impossible, just not as easy as my old eyes would like! Overall, I'm very satisfied with my manual, and I will certainly be using this company again. Well done.
 ;
I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, pages are very clear to read, some of the pages are a bit tilted but overall it is great to have this manual available for purchase. Thanks
 ;
This is quiet a rare manual, I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, Excellent guide: very clear, enabling us to print readable diagram overall it is great to have this manual available for purchase. This is a complete service manual no pages are missing. Thanks
 ;
This SM is quiet scarce and hard to find it is an excellent Service manual, very clear to read and to print schematics and diagrams, Hi quality, Complete manual with no pages missing. I am very pleased with the manual and the fast service I have received. Great place to shop.
Good luck finding you manual...
 ;
Quick delivery, the document was usefull, although the copy was i little bit unclear in the details.
SECTION 3 SET-UP ADJUSTMENTS
3-1. SCREEN VOLTAGE ADJUSTMENT (ROUGH ALIGNMENT)
1. Receive the Monoscope signal. 2. Set 50% BRIGHTNESS and minimum PICTURE. 3. Turn the red VR on the FOCUS block all the way to the left and then gradually turn it to the right until the point where you can see the retrace line. 4. Next gradually turn it to the left to the position where the retrace line disappears.
KP-41S5/41S5B/41S5G/ 41S5K/41S5R/41S5U
RM-862
3-3. SCREEN (G2) ADJUSTMENT
1. 2. 3. 4. Connect jig (A) to 200V. In TP732, CG Board. Connect jig (B) to GND. In TP733, CG Board. Select with Power ON, VIDEO mode without signals. Connect jig (C) to the TP701 (K.CR), TP731 (K:CG), or TP761 (K.CB) of CR, CG, and CB Board. 5. Adjust R, G, and B screen voltage to until retrace line just appears with screen VR on the Focus block
KR-KG-KB (C)
2.2k / 3W x2
R
G SCREEN
B
5.6k / 3W
(B) GND
2.2k / 3W
B
R
G FOCUS
(A) 200V
Fig. 3-3
FOCUS block Fig. 3-1
3-4. FOCUS VR ADJUSTMENT
1. Set in service mode. 2. Use GH (GSEL) on the service mode menu to shown only the green color. 3. Press the Commander Menu button (convergence) and output the test signal (crosshach). 4. Rotate the green VR on the FOCUS block and align to obtain the optimal focus point. 5. Use GH (GSEL) from the service mode menu to set to green and red. 6. Output the test signal and rotate the red VR to obtain the optimum focus at the point where the red and green spots overlap. 7. Use BH (BSEL) from the service mode menu to set to red and blue. 8. Output the test signal and rotate the blue VR aligning to obtain the optimum focus at the point where the blue and green spots overlap.
3-2. FOCUS LENS ADJUSTMENT
1. Loose the lens screw. 2. Set in service mode. 3. Use GH (GSEL) on the service mode menu to shown only the green color. 4. Press the Commander Menu button and select TEST MENU and CONVERGENCE to display the test signal (crosshatch) on the screen. 5. Rotate the green lens and align with the optimal focus point from the test signal. 6. Use GH (GSEL) from the service mode menu to set to green and red. 7. Output the test signal and rotate the red lens to obtain the optimum focus at the point where the red and green spots overlap. 8. Use BH (BSEL) from the service mode menu to set to red and blue. 9. Output the test signal and rotate the blue lens to obtain the optimum focus at the point where the blue and red spots overlap. 10. Tighten the lens screw.
Scanning line visible. Scanning line visible.
A Minimize both AA and B. A Minimize both and B.
Lens Fig. 3-4 Test signal Fig. 3-2
B B
Fig. 3-5
� 19 �
|
|
 |
> |
|