Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
We received the manual in a timely manner and it was exactly what we were expecting.
 ;
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
 ;
Very good scanning quality. All schematics are very legible. Worth every cent !
 ;
Excellent quality, very quick download turnaround, will definately use again.
 ;
This is a awesome quality scan of the original Service Manual for Technics 8099.
Contains the circuit diagram, PCB layout, adjust/tune instructions as well.
Since this is my first buy here, i'm really glad! This site do works as intended/described, it's definitely not scam!
Мои рекомендации! Все мануалы настоящие!
KRC-2902YA/G
COMPONENTS DESCRIPTION
q SYNTHESIZER UNIT (X14-6872-73)
Ref.No.
IC1 IC2 IC3 IC4 IC5 IC6 Q49 Q50 Q51,52 Q53 Q54,55 Q56,57 Q58,59 Q60,61 Q150 Q151 Q201 Q203 Q260 Q261 Q301 Q320 Q350 Q351 Q352 Q353
Function
SYSTEM µ-COM E -VOLUME M UTE LOGIC POWER AMPLIFIER EQUALIZER AMPLIFIER RESET A CC DETECTION SW BACK-UP DETECTION SW BACK-UP 5V DRIVER P.ON 5V SW 8V SW 8V DRIVER ILLUMI +B SW ILLUMI +B DRIVER E-VOL MUTE SW Controls the unit. Controls the volume and selects source. Controls the mute output. For the speaker output. For the cassette tape's signal. Resets the power. Outputs "H" during the ACC off.
Operation
Outputs "H" when the back-up voltage is under 9.2V. Works when back-up current exists. Works during the power on. Works during the power on. Works during the power on. Works during the power on. Works during the power on. Works when the back-up current is detected or the changer mute works or system µ-com mute works.
SVR FORCED DISCHARGE SW Works when the amplifier mute works. FM +B SW AM +B SW MOTOR +B SW MOTOR +B DRIVER CD-CH RESET SW PANEL 5V SW P.CON DRIVER SW P.CON PROTECTION SW Works during FM mode. Works during AM mode. Works during the tape mode. Works when Q206 works. Works when the power is reset and the reset SW works. Works when the back-up current exists and the panel is attached on the unit. Does not work during the power off and the ALL OFF. Works when the P.CON is short-circuited on the GND.
P.CON PROTECTION INHIBIT SW Inhibits the protection SW in a moment during the P.CON on. P.CON DRIVER SW Does not work during the power off and the ALL OFF.