This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
KRC-778R/RV/RY/RYV,878R,PS978R
TEST MODE
(12.2) Procedure for canceling the MASK key request (when the set is reset or the back-up power is turned off while the MASK key is enabled)
1. When the power is supplied and the set is switched on, "TRANSMIT1" is displayed and the MASK key request mode starts. 2. Point the MASK key toward the light sensor and press and hold for more than 3 seconds (until the level indicator indicates the full condition). 3. When "TRANSMIT2" is displayed, press and hold the MASK key again for more than 3 seconds.If "TRANSMIT1" is displayed now, go back to step 2 and restart from there again. 4. When "APPROVED" is displayed, the MASK key is enabled and the set is turned on.
(13) Other
o Automatic panel closing when the TAPE/CD/MD is inserted is disabled. o Pressing the ATT key ON/OFF opens or closes the panel. (The ATT operation can be activated from the remote control unit.) o The DNPP/SBF key of the remote control unit (RC-510) functions as the menu mode ON/OFF key. o The OPEN/CLOSE key of the remote control unit (RC510) functions as the audio adjustment mode ON/OFF key. o The menu feed operations occur only with the necessary features. o Display such as "CODE OFF" is not displayed at the moment power is turned on. o Pressing the TI (AUTO) key during the changer operation turns 2zone on, and pressing the TI (AUTO) key again cancels it. The P/S dot lights during the 2zone operation. o Pressing and holding the MENU key for more than 1 second while ALL OFF initiates the MASK KEY write mode. o The dimmer control of the FL models or the contrast control of the LCD models can be adjusted only to 0/5/10 using the UP/DOWN keys.
(12.3) Procedure for MASK key initialization (Resetting the MASK key enabled condition to the factory-set condition)
1. While holding the FM and preset 6 keys, press RESET to enter the test mode. 2. "TRANSMIT1" is displayed and the MASK key request mode starts.At this time, the display shows "* *" in place of "[ ]". 3. Press the MASK key cancel remote control for more than 3 seconds. 4. When "TRANSMIT2" is displayed, press and hold the MASK key again for more than 3 seconds. 5. When "APPROVED" is displayed, the MASK key is canceled, the demonstration mode is set, the test mode is canceled and the set returns to the factory-set condition.
(12.4) MASK key all-clear procedure
1. While holding the FM and preset 6 keys, press RESET to enter the test mode. 2. Press and hold the AUDIO key for more than 1 second to enter the menu mode. 3. Press the Track UP/DOWN key to select "Mask key". 4. Press and hold the FM or AM key for more than 2 seconds so that "TRANSMIT1" is displayed. 5. Point the MASK key cancel remote control toward the light sensor and press for more than 3 seconds (until the level indicator indicates the full condition). 6. When "TRANSMIT2" is displayed, press and hold the MASK key again for more than 3 seconds.If "TRANSMIT1" is displayed now, go back to step 2 and restart from there again. 7. When "APPROVED" is displayed, the E2PROM is cleared entirely and the condition in "(14) MASK key write procedure in production line (when the E2PROM is in the initial status)" returns.