Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Excellent high quality schematics brought my old Heidelberg back to life. Fast download at a reasonable price. Thanks.
 ;
This document is just what I was looking for, it´s very useful, it contains adjustment procedures for the final stage of the power amp and also
has a complete wiring diagram and description of the main semiconductors used in the design.
 ;
Dear Sirs,
Thank you for the fast support, the manual does provide all necessary information to repair the radio. All schematics are in a good quality for reading.
The manual fits 100% to my requirements as a technican.
Kind regards Thomas
 ;
the big video recorder format s-vhs many features delicate in loading system of the cassette. Such machines are no longer manufactured, it would be too expensive.
 ;
THIS MANUAL IS VERY GOOD AND VERY CLEAR
PLEASE NOTE IT DOES NOT CONTAIN THE SETUP INFORMATION TO ALIGHN THE GEARS IN THE CD MECH IT DOES SHOW ALL THE PARTS AND THEIR LOCATIONS .
KRF-V5050D/V5550D/V6050D/V7050D/X9050D
CIRCUIT DESCRIPTION
4. AK4112AVF u-com interface port
Pin Name Pin No. PD 7 AUTO 5 FS96 17 ERF 18 CSN 25 CCLK 26 CDTI 27 CDTO 28 I/O I O O O I I I O Function Power Down Mode Pin When "L", the AK4112AVF is power down and reset. Non PCM Detect Pin "L":No detect, "H":Detect 96kHz Sampling Detect Pin "H":fs=88.2kHz or more, "L":fs=54kHz or less. Unlock & Parity Error Output Pin "L":No Error, "H":Error Chip Select pin in Serial Mode Control Data Clock Pin in Serial Mode Control Data Input Pin in Serial Mode Control Data Output Pin in Serial
5. AK4527B u-com interface port
Pin Name Pin No. PDN 17 OVF 33 CSN 41 CCLK 42 CDTI 43 I/O I O I I I Function Power Down & Reset Pin Analog Overflow Detect Pin Chip Select Pin Control Data Clock Pin Control Data Input Pin
6. Test Mode
6-1 Entering the Test Mode
� While pressing the "BAND" key, plug the power cord into AC wall outlet.
6-2 Cancelling the Test Mode
� Initialized and cancel the test mode if pulling out the power code.
6-3 Contents of the Test Mode 6-3-1 Pch CALL UP/DOWN
Key DIMMER Function Pch CALL UP ... 01 02 03 Pch CALL DOWN ... 01 02 03
... ...
39 40
INPUT MODE
39 40
6-3-2 10 Steps Switching of P ch Call
Key SET UP Function Preset Operation
6-3-3 TUNER mute on/off
Key LISTEN MODE Function TUNER mute on/off
6-3-4 Key Operation
� The following operation is available during the all FL lighting up mode only.(only VR-507/509/510) Operation Keys Display Function SOUND Normal Indication RF receiving frequency is made 422MHz for VR-509/510 and 418MHz for VR-507. LISTEN MODE FRONT IR FRONT IR is enabled and remote control is disabled. SOURCE DIRECT RF BAND 2 RF receiving frequency is made 428MHz for VR-509/510.
8
|
|
 |
> |
|