Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the original manufacturers service manual, with detailed info on the circit boards, explosion drawings of all parts in assembly order, and tuning instructions. The only thing missing is the information on the dimensions of the various drive belts. mail me if you need them. gcrossman_at_aol.com
 ;
Ordered service manuel for a hard to find plasma tv - your company made it easy to find and purchase - I will use you again
Thanks for your help
 ;
This is a high quality manual with clear schematic and components layout diagrams ; with service procedure included.
 ;
This service manual for the Kenwood KT-990D was reproduced really well ,is very legible and manual is complete.Combined with the low price paid,in the future,I will be checking Owner-Manuals.com any time I need a manual.
 ;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
(-
KV-133;fW&�,
3-2.
l l l
CONVERGENCE
:
4.
Preparation
When the V.STAT magnet is moved in the direction of arrow @ and @ , Red, Green and Blue dots move as shown below.
Before starting, perform FOCUS, H. SIZE and V. SIZE adjustments. Set BRIGHTNESS control to fully counterclock wise. Feed in the dot pattern.
(1) Horizontal and Vertical Static Convergence
Center dot
El
G DRIVE
B
G
I
R
B BKG G BKG R BKG
SUB BRT
1.
Adjust H. STAT VR to coincide red, green and blue dots on the center of screen. (Horizontal movement) Adjust V. STAT magnet to coincide red, green and blue dots on the center of screen. (Vertical movement) If the red, green and blue dots do not coincide on the center of screen with H. STAT VR, perform horizontal convergence adjustment using H. STAT VR and V. STAT magnet as shown below. (In this case, H. STAT VR and V. STAT magnet effect each other.) Tilt the V.STAT magnet and adjust static convergence to open or close the V. STAT magnet.
If blue dot dose not coincide with red and green dots, perform following steps. Move BMC magnet (a) to correct insufficient H. static convergence. Rotate BMC magnet (b) to correct insufficient V. static convergence. In either case, repeat Beam Landing Adjtstment.
2.
3.
MC Magnet
0
- 13 -
|
|
 |
> |
|