Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
 ;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
FE-1A SELF DIAGNOSTIC SOFTWARE
The identification of errors within the FE-1A chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with continuous flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number will be displayed through the LED (Series of flashes which must be counted) See Table 1., non fatal errors are reported using this method. Each time the software detects an error it is stored within the NVM. See Table 2.
Table 1
ERROR No error Not allowed (may be confused with Sircs response flash!) Protection circuit trip < ANY TIME > Reserved No vertical sync AKB IIC bus clock and/or data lines low at Power ON NVM no IIC bus acknowledge at Power ON Jungle controller no IIC acknowledge at Power ON Tuner no acknowledge at Power ON Sound processor no acknowledge at Power ON LED ERROR COUNT 00 01 02 03 04 05 06 07 08 09 10
How to enter into Table 2
1. 2. Turn on the main power switch of the TV set and enter into the �Standby Mode�. Press the following sequence of buttons on the Remote Commander.
i+
(ON SCREEN DISPLAY)
5
(DIGIT 5) (VOLUME -) (TV)
3.
The following table will be displayed indicating the error count.
Table 2
Error Times -
Flash Timing Example : e.g. error number 3
StBy LED ON ON ON
2 3 4 5 6 7 8 9 10
OFF
OFF
Note: To clear the error count data press �80� on the Remote commander.
6
|
|
 |
> |
|