Some of the pictures in this manual are a bit irritating. I had to dissassemble the unit and some of the screws have different threads, which is not mentioned in this manual. Also some of the drawings of the boards look different than the actual boards.
After all, the manual was very useful. I was able to recalibrate the capstan drive and it is working fine again.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
KV-29X5
3-2. CONVERGENCE
Preparation:
� � � Before starting this adjustment, adjust the focus, horizontal size and vertical size. Minimize the Brightness setting. Input a dot pattern from the pattern generator.
�
Tilt the V.STAT magnet and adjust the static convergence by opening or closing the V.STAT magnet.
(1)
Horizontal and vertical static convergence
4. If the V.STAT magnet is moved in the direction of the a and b arrows, the Red, Green and Blue points move as indicated below.
Centre dot
R G B
RG
B
H.STAT
V.STAT Magnet
C Board RV701 SCREEN RV702
1.
2.
3.
[Moving horizontally], adjust the H.STAT control so that the Red, Green and Blue points are on top of each other at the centre of the screen. [Moving vertically], adjust the V.STAT magnet so that the Red, Green and Blue points are on top of each other at the centre of the screen. If the H.STAT variable resistor is unable to bring the Red, Green and Blue points together at the centre of the screen, adjust the horizontal convergence with the H.STAT variable resistor and the V.STAT magnet in the manner indicated below. [In this case, the H.STAT variable resistor and the V.STAT magnet influence each other].
17
|
|
 |
> |
|