Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It was helpful to get schematic with waveforms in important points and lot of service information. Manual is good quality, fast delivered. Of course it is hardcopy of paper one with all its disadvantages.
 ;
I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
 ;
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
 ;
Complete manual including mechanical part in good pdf quality. Shaded greys of the pcb due to pdf not perfect but usable.
 ;
Nice pdf file of the manual sent promptly. Thanks.
KV-27HS420/29DRC430/30HS420/32HS420/34HS420
1-4. PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove the anode cap. Short between anode and CRT coated earth ground strap. 7 10 8 6 3 5 4 3 1. Discharge the anode of the CRT and remove the anode cap. 2. Unplug all interconnecting leads from the de�ection yoke, neck assembly, degaussing coils and CRT grounding strap. 3. 4. 5. 6. 7. Remove the CH Board from the CRT. Remove the chassis assembly. Loosen the neck assembly �xing screw and remove. Loosen the de�ection yoke �xing screw and remove. Place the set with the CRT face down on a cushion
Coated Earth Ground Strap
1
2
9
4
and remove the degaussing coil holders. 8. Remove the degaussing coils. 9. Remove the CRT grounding strap and spring tension devices. 10. Unscrew the four CRT �xing screws [located on each CRT corner] and remove the CRT [Take care not to handle the CRT by the neck].
ANODE CAP REMOVAL PROCEDURE
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove the anode cap. After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT. NOTE: After removing the anode cap, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield or carbon painted on the CRT.
REMOVAL PROCEDURES
c
a
b
Anode Button
Turn up one side of the rubber cap in the direction indicated by arrow a .
Use your thumb to pull the rubber cap �rmly in the direction indicated by arrow b .
HOW TO HANDLE AN ANODE CAP
1. Do not use sharp objects which may cause damage to the surface of the anode cap. 2. To avoid damaging the anode cap, do not squeeze the rubber covering too hard. A material �tting called a shatter-hook terminal is built into the rubber. 3. Do not force turn the foot of the rubber cover. This may cause the shatter-hook terminal to protrude and damage the rubber.
When one side of the rubber cap separates from the anode button, the anode cap can be removed by turning the rubber cap and pulling it in the direction of arrow c .
KV-27HS420/29DRC430/30HS420/32HS420/34HS420