Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Exactly the JVC service manual and schematics that I was looking for - delivered just hours after order. Will do business again!
 ;
This is a fantastic site, ad I have been a returning satisfied cusumer!
Thanx for a great sevice!
 ;
Je suis audiophile belge, électronicien et créateur d'enceintes acoustiques.
J'ai apprécié la qualité des documents fournis. Ils sont très lisibles, ils peuvent être agrandis sans problème et ils sont complets. Pour moi, c'est parfait. Pour cette qualité, je suis d'accord de payer. Et le système de paiement et d'envoi est simple. Merci, continuez comme cela.
Frédéric
 ;
The cover page was a little scary, very dark but readable. The remainder of the document was better copy and easily readable. Why would I give 5 Stars? (1) PRICE, (2) AUTHENTICITY, It was the real deal, filled with service information, including the specific information I required. (3) PRIVACY, I didn't start to get slammed with spam. (4) EASY TRANSACTION. Painless. (5) COMPLETE, I have found several manuals here, that I could find nowhere else. (6) I will be a repeat customer!
 ;
Well done!!! I found what I need to have, indeed!
Furthermore, due to my hobby is repairing vintage equipments, I added this web site in my desk toolbar because I have in mind to search further service manuals. Thanks a lot www.owner-manuals.com !
Regards, Maurizio
KV-EF29M31/EF29M61/EF29M80/RM-881 EF29M90/EF29M91/EF29M80/RM-881
�
Operation of BMC (Hexapole) Magnet If the red, green and blue dots are not balanced or aligned, then use the BMC magnet to adjust in the manner described below.
RG B R G B R GB
�
Use the H.STAT VR to adjust the red, green, and blue dots so that they coincide at the center of screen. The respective dot position resulting from moving each magnet interact, so be sure to perform adjustment while tracking.
R G
B R G B R G B
1
Y separation axis correction magnet adjustment receive the cross-hatch signal and adjust [PICTURE] to [MIN] and [BRIGHTNESS] to [STANDARD] .
2
Adjust the Y separation axis correction magnet on the neck assembly so that the horizontal lines at the top and bottom of the screen are straight.
BLUE
VM Board
RED
RED
BLUE VM Board
Note 1) The Red and Blue magnets should be equally far from the horizontal center line. 2) Do not seperate the Red and Blue magnets too far. (Less than 8 mm)
� 28 �
|
|
 |
> |
|