|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very Good! All the diagram are easy to read, and its complete.
 ;
This was an excellent source of detailed assembly information on a device which is at least 12 years old. A very lucky find, coupled with great service.
 ;
Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
 ;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
 ;
I really like this manual and it's reliable.I found and bought easly.thank you.
KV-ES34M31/ES34M61/ES34M80/ES34M90
RM-916
4 BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then use the BMC magnet to adjust in the manner described below.
RG B R G B R GB
(2) Dynamic Convergence Adjustment Preparation: � Before starting this adjustment, adjust the horizontal static � convergence and the vertical static convergence Set the PICTURE and BRIGHTNESS to normal.
1. Adjust TLH. (TLH correction piece) 1 Receive the dot/hatch pattern signal and adjust picture quality by the menu.
R G B R G B R G B
2 Correct horizontal mis-convergence of red and blue of both sides on the X axis. When red is outside insert BMC magnet to right side (THL+) views from DY neck. And when blue is outside, insert it to left side (THL�) and take both sides.
RB (B) (R) B R TLH + (R) (B) TLH -
5 Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN] and [BRIGHTNESS] to [STANDARD] . 2. Adjust the Y separation axis correction magnet on the neck assembly so that the horizontal lines at the top and bottom of the screen are straight.
Blue Neck assy Neck assy Red
2. Adjust V TILT-TLV (TLV 34") Correct the vertical mis-convergence of red and blue of vertically sides on the Y axis. 3. Adjust YCH. Adjust horizontal mis-convergence of red and blue of vertically sides on the Y axis. Mentioned above steps 2 to 4 are adjusting respectively perform minuteness tracking.
Red
Blue
YCH
VM board VM board
H-TRP TLV BMC magnet C board
Note 1. The Red and Blue magnets should be equally far from the horizontal center line. 2. Do not separate the Red and Blue magnets too far. (Less than 8 mm)
VM board
RV9001
� 44 �
|
|
 |
> |
|