Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Fully functional usable service manual. Considering the age of the manual and device quality was better than expected
 ;
Thank you very much, I've been very happy to find this manual on "Owner Manual". It's a perfect copy and it has been really useful for my work!
 ;
It took about 24-hours after my payment before I was able to get to the download. Apparently, payment processing is not 100% automated. That is no big deal, just be aware of that going in.
After I got to it, it was in good shape, easy to read, etc. Not some cheap FAX copy looking thing.
Also, this site was the cheapest I found. Another Plus!
 ;
Good price, very legible manual, exactly what I needed -- but had to wait a day to actually get the download of the manual. Would have preferred to download it immediately after payment rather than waiting for someone to "process" my order. I was surprised that I had to wait that long.
 ;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
KV-ES34M61/ES34N90
RM-916 RM-958
6.
SELF-DIAGNOSTIC CIRCUIT
IC4301 RGB JUNGLE OVP OCP FROM CRT (IK) [H] IC6801 [V] D6806/D6801 3 25 IKIN 6 20 XRAY
IC001 SYSTEM SDA 5
IC003 MEMORY
LED 54 16 V PROT SDA 5 CXA2100Q IC004 MEMORY
[+B overcurrent ªOCPº]
Occurs when an overcurrent on the +B(135) line is detected by Q6610 and Q6609. If Q6610 and Q6609 go to ON, the voltage to the pin3 of IC001 go to UP. The unit will automatically turn off. Occurs when an overvoltage on the +B(135) line is detected by D6635, Q6611 and Q6612. If Q6611 and Q6612 go to ON, the voltage to pin6 of IC001 go to UP. The unit will automatically turn off. Occurs when an absence of the vertical deflection pulse is detected by Q6811, Q6819, Q6820, Q6821 and D6801. Shut down the power supply. If the RGB levels do not balance or become low level within 5 seconds. This error will be detected by IC4301. TV will stay on, but there will be no picture. Occurs when an overvoltage of horizontal pulse is detected by D6809 and IC6801. If the voltage of 7 pin of IC6801 goes to High, the voltage to pin20 of IC4301 go to UP. The unit will automatically turn off.
[+B overvoltage ªOVPº]
[Vertical deflection failure] [White balance failure]
[High voltage protector of Horizontal Deflection]
�8�
|
|
 |
> |
|