RM-869
5-2. ADJUSTMENT METHOD
Item Number 08 This explanation uses V-SHIFT as an example. 1. Select 08 V-SHIFT with the 1 and 4 buttons. 2. Raise/lower the data with the 3 and 6 buttons. 3. Select the optimum state. (The standard is 0F for PAL reception.) 4. Write with the MUTING button. 5. Execute the writing with the - button. (The WRITE display returns to green SERVICE.) Use the same method for Items Number 00-40. Use 1 and 4 to select the adjustment item, use 3 and 6 to adjust, write with MUTING , then execute the write with -.
08 052S
VSF V3.2C
0C 00
SERVICE 50
GREEN
Adjusted with 3 and 6 buttons
08 052S
VSF V3.2C
0C 00
WRITE 50
GREEN
Written with MUTING
08 Blank
VSF
0C
WRITE
GREEN The WRITE display will change back to SERVICE. (2nd line disappear when written)
Write executed with 0