Who's Online
There currently are 5761 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
More than pleased with my prurchase, very good product for the price.
;
Manual-link came 30 minutes after having paid for an extremely rare (40 years old) item (sony icr-120) and helped me to get the radio rework again. So really good help for me, fast and reliable delivery and -taken that into consideration- a very reasonable price for that service. So thanks again! Mike, Germany
;
Some of the pictures in this manual are a bit irritating. I had to dissassemble the unit and some of the screws have different threads, which is not mentioned in this manual. Also some of the drawings of the boards look different than the actual boards.
After all, the manual was very useful. I was able to recalibrate the capstan drive and it is working fine again.
;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
KV-HA14L80/HA14P50
RM-969
SECTION 3 SET-UP ADJUSTMENTS
The following adjustments should be made when a complete realignment is required or a new picture tube is installed. These adjustments should be performed with rated power supply voltage unless otherwise noted. Controls and switches should be set as follows unless otherwise noted: PICTURE control ........................................................... normal BRIGHTNESS control ................................................... normal Perform the adjustments in the following order : 1. Beam Landing 2. Convergence 3. Focus 4. White Balance Note : Test Equipment Required. 1. Pattern Generator 2. Degausser 3. Oscilloscope
................................................................................................................................................................................................................................
Preparation : In order to reduce the influence of geomagnetism on the set's picture tube, face it east or west. Switch on the set's power and degauss with the degausser.
Purity control
3-1. BEAM LANDING
1. Input a white signal with the pattern generator. Contrast normal Brightness
}
2. Set the pattern generator raster signal to a green raster. 3. Move the deflection yoke to the rear and adjust with the purity control so that the green is at the center and the blue and the red take up equally sized areas on each side. (See Figures 3-1 through 3-4.) 4. Move the deflection yoke forward and adjust so that the entire screen is green. (See Figure 3-1.) 5. Switch the raster signal to blue, then to red and verify the condition. 6. When the position of the deflection yoke has been decided, fasten the deflection yoke with the screws and DY spacers. 7. If the beam does not land correctly in all the corners, use a magnet to adjust it. (See Figure 3-4.)
Fig. 3-2
Blue Red Green
Fig. 3-3
Purity control corrects this area.
b a
Disk magnets or rotatable disk magnets correct these areas (a-d).
c
d
Deflection yoke positioning corrects these areas. b
c a
Fig. 3-1
d
Fig. 3-4