Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
 ;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
 ;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
 ;
I will definitely be back for more information when I need it.
 ;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
KV-HA14L80/HA14P50
RM-969
SECTION 3 SET-UP ADJUSTMENTS
The following adjustments should be made when a complete realignment is required or a new picture tube is installed. These adjustments should be performed with rated power supply voltage unless otherwise noted. Controls and switches should be set as follows unless otherwise noted: PICTURE control ........................................................... normal BRIGHTNESS control ................................................... normal Perform the adjustments in the following order : 1. Beam Landing 2. Convergence 3. Focus 4. White Balance Note : Test Equipment Required. 1. Pattern Generator 2. Degausser 3. Oscilloscope
................................................................................................................................................................................................................................
Preparation : In order to reduce the influence of geomagnetism on the set's picture tube, face it east or west. Switch on the set's power and degauss with the degausser.
Purity control
3-1. BEAM LANDING
1. Input a white signal with the pattern generator. Contrast normal Brightness
}
2. Set the pattern generator raster signal to a green raster. 3. Move the deflection yoke to the rear and adjust with the purity control so that the green is at the center and the blue and the red take up equally sized areas on each side. (See Figures 3-1 through 3-4.) 4. Move the deflection yoke forward and adjust so that the entire screen is green. (See Figure 3-1.) 5. Switch the raster signal to blue, then to red and verify the condition. 6. When the position of the deflection yoke has been decided, fasten the deflection yoke with the screws and DY spacers. 7. If the beam does not land correctly in all the corners, use a magnet to adjust it. (See Figure 3-4.)
Fig. 3-2
Blue Red Green
Fig. 3-3
Purity control corrects this area.
b a
Disk magnets or rotatable disk magnets correct these areas (a-d).
c
d
Deflection yoke positioning corrects these areas. b
c a
Fig. 3-1
d
Fig. 3-4
� 14 �
|
|
 |
> |
|