Operation of BMC (Hexapole) Magnet If the red, green and blue dots are not balanced or aligned, then use the BMC magnet to adjust in the manner described below.
�
Use the H.STAT VR to adjust the red, green, and blue dots so that they coincide at the center of screen. The respective dot position resulting from moving each magnet interact, so be sure to perform adjustment while tracking.
RG
B
R
G
B
R
GB
R
G
B
R
G
B R
G B
1
Y separation axis correction magnet adjustment receive the cross-hatch signal and adjust [PICTURE] to [MIN] and [BRIGHTNESS] to [STANDARD] . Adjust the Y separation axis correction magnet on the neck assembly so that the horizontal lines at the top and bottom of the screen are straight.
BLUE Paint
2
VM Board
RED Paint
RED Paint
BLUE Paint VM Board
Note 1) The Red and Blue magnets should be equally far from the horizontal center line. 2) Do not seperate the Red and Blue magnets too far. (Less than 8 mm)
� 17 �
|
|
 |
> |
|