A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
 ;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
 ;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
 ;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
CT-401/403/KXF-W1030/W3030
ADJUSTMENT
No. ITEM INPUT SETTINGS OUTPUT SETTINGS CASSETTE DECK SETTINGS ALIGNMENT POINT ALIGN FOR 0 dBs = 0.775 V Demagnetize the REC/PLAY head with a head demagnetizer. Clean the REC/PLAY head, erase head, capstan and pinch roller using a cotton swab slightly damped with alcohol. Maximum output. (a) (b) FLG. CASSETTE DECK SECTION I. REC/PLAY HEAD [1] DEMAGNETIZATION � � POWER OFF Remove the cassette door. REC/PLAY head REC/PLAY head, erase head, capstan pinch roller Azimuth adjustment screw TAPE: NORMAL, DOLBY: OFF, INPUT: LINE IN
[2]
CLEANING
�
�
PLAY
[3]
AZIMUTH
(A) MTT·114, TCC-153 0 kHz, -10 dB
(B)
PLAY
II. DC BOARD [1] TAPE SPEED (A) MTT-111, TCC-110 3 kHz (B) PLAY SFR301 Adjust the tape speed so that a 3 kHz signal is produced at the center of the tape.
III. PC BOARD <1> <2> PLAYBACK LEVEL RECORD LEVEL MTT-150 400 Hz (200 nWb) (A) 1 kHz, -20 dBs (A) 1 kHz, -20 dBs 10 kHz, -20 dBs (B) PLAY Record 1kHz and 10kHz in alternation and playback. DECK B SFR101 (L) SFR102 (R) SFR107 (L) SFR108 (R) Output level : ±1 dBs 0 dBs ± 3 dBs Record 1 kHz and 10 kHz in alternation and adjust the variable resistors which control the bias current so that the playback level is obtained 0 dBs ± 3 dBs. 105 kHz ± 3 kHz (c)
(B)
<3>
BIAS CURRENT
(B)
Record and playback at maximum REC volume position.
SFR105 (L) SFR106 (R)
<4>
REC BIAS OSC FREQUENCY
�
�
Recording
L107
SYSTEM CONNECTIONS
(a) AZIMUTH ADJUSTMENT
SYSTEM CONTROL
REC PLAY
L
R
LINE IN LINE OUT
AC voltmeter
AG
Oscilloscope
AC voltmeter Frequency counter
(A)
(B)
KXF-W1030
(b) AZIMUTH ADJUSTMENT
(c)
To Frequency counter
CN105
4
KXF-W3030
|
|
 |
> |
|