This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
CT-401/403/KXF-W1030/W3030
ADJUSTMENT
No. ITEM INPUT SETTINGS OUTPUT SETTINGS CASSETTE DECK SETTINGS ALIGNMENT POINT ALIGN FOR 0 dBs = 0.775 V Demagnetize the REC/PLAY head with a head demagnetizer. Clean the REC/PLAY head, erase head, capstan and pinch roller using a cotton swab slightly damped with alcohol. Maximum output. (a) (b) FLG. CASSETTE DECK SECTION I. REC/PLAY HEAD [1] DEMAGNETIZATION � � POWER OFF Remove the cassette door. REC/PLAY head REC/PLAY head, erase head, capstan pinch roller Azimuth adjustment screw TAPE: NORMAL, DOLBY: OFF, INPUT: LINE IN
[2]
CLEANING
�
�
PLAY
[3]
AZIMUTH
(A) MTT·114, TCC-153 0 kHz, -10 dB
(B)
PLAY
II. DC BOARD [1] TAPE SPEED (A) MTT-111, TCC-110 3 kHz (B) PLAY SFR301 Adjust the tape speed so that a 3 kHz signal is produced at the center of the tape.
III. PC BOARD <1> <2> PLAYBACK LEVEL RECORD LEVEL MTT-150 400 Hz (200 nWb) (A) 1 kHz, -20 dBs (A) 1 kHz, -20 dBs 10 kHz, -20 dBs (B) PLAY Record 1kHz and 10kHz in alternation and playback. DECK B SFR101 (L) SFR102 (R) SFR107 (L) SFR108 (R) Output level : ±1 dBs 0 dBs ± 3 dBs Record 1 kHz and 10 kHz in alternation and adjust the variable resistors which control the bias current so that the playback level is obtained 0 dBs ± 3 dBs. 105 kHz ± 3 kHz (c)
(B)
<3>
BIAS CURRENT
(B)
Record and playback at maximum REC volume position.
SFR105 (L) SFR106 (R)
<4>
REC BIAS OSC FREQUENCY
�
�
Recording
L107
SYSTEM CONNECTIONS
(a) AZIMUTH ADJUSTMENT
SYSTEM CONTROL
REC PLAY
L
R
LINE IN LINE OUT
AC voltmeter
AG
Oscilloscope
AC voltmeter Frequency counter
(A)
(B)
KXF-W1030
(b) AZIMUTH ADJUSTMENT
(c)
To Frequency counter
CN105
4
KXF-W3030
|
|
 |
> |
|