Who's Online
There currently are 5005 guests and 2 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
- Very good scan quality, PERFECT!
- Sehr gute scan Qualitaet, empfehlenswert!
Wolfgang Sundhaus
;
Good site, works ok and you get what you order, no problems experienced, got my manual within a day. A++++
;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
CT-401/403/KXF-W1030/W3030
ADJUSTMENT
No. ITEM INPUT SETTINGS OUTPUT SETTINGS CASSETTE DECK SETTINGS ALIGNMENT POINT ALIGN FOR 0 dBs = 0.775 V Demagnetize the REC/PLAY head with a head demagnetizer. Clean the REC/PLAY head, erase head, capstan and pinch roller using a cotton swab slightly damped with alcohol. Maximum output. (a) (b) FLG. CASSETTE DECK SECTION I. REC/PLAY HEAD [1] DEMAGNETIZATION � � POWER OFF Remove the cassette door. REC/PLAY head REC/PLAY head, erase head, capstan pinch roller Azimuth adjustment screw TAPE: NORMAL, DOLBY: OFF, INPUT: LINE IN
[2]
CLEANING
�
�
PLAY
[3]
AZIMUTH
(A) MTT·114, TCC-153 0 kHz, -10 dB
(B)
PLAY
II. DC BOARD [1] TAPE SPEED (A) MTT-111, TCC-110 3 kHz (B) PLAY SFR301 Adjust the tape speed so that a 3 kHz signal is produced at the center of the tape.
III. PC BOARD <1> <2> PLAYBACK LEVEL RECORD LEVEL MTT-150 400 Hz (200 nWb) (A) 1 kHz, -20 dBs (A) 1 kHz, -20 dBs 10 kHz, -20 dBs (B) PLAY Record 1kHz and 10kHz in alternation and playback. DECK B SFR101 (L) SFR102 (R) SFR107 (L) SFR108 (R) Output level : ±1 dBs 0 dBs ± 3 dBs Record 1 kHz and 10 kHz in alternation and adjust the variable resistors which control the bias current so that the playback level is obtained 0 dBs ± 3 dBs. 105 kHz ± 3 kHz (c)
(B)
<3>
BIAS CURRENT
(B)
Record and playback at maximum REC volume position.
SFR105 (L) SFR106 (R)
<4>
REC BIAS OSC FREQUENCY
�
�
Recording
L107
SYSTEM CONNECTIONS
(a) AZIMUTH ADJUSTMENT
SYSTEM CONTROL
REC PLAY
L
R
LINE IN LINE OUT
AC voltmeter
AG
Oscilloscope
AC voltmeter Frequency counter
(A)
(B)
KXF-W1030
(b) AZIMUTH ADJUSTMENT
(c)
To Frequency counter
CN105
4
KXF-W3030
|
|
|
> |
|