Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
 ;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
 ;
In a word AWESOME.
I never expected the quality and abundant content that I got with this manual. Everything you'd ever want to know from a service perspective is found in this manual, along with... as a bonus, operating instructions on how to use the unit. WOW. Very impressed with the quality of the manual. You won't be disappointed if you're looking for the EVS900 service manual.
 ;
I thank Owen-Manuals.com for the wonderful service rendered to me, and this manual which I purchased helped me a lot in servicing my Denon System, which was lying in a dead state.
Thanks Owner-Manual.com
 ;
I purchased this manual to repair my Teac set and with the support of this manual I rectified the problem.
Thanks Owner-Manuals.com
micro switch has broken, and the timer should be replaced by a new one. If all the above examination shows normal ,then check whether the terminal p�ug of the magnetron and the capacitor have loosened, if it is loosened, pinch it tightly with a pliers. 5.2.5 EXAMINE THE STARTING AND THE 8A FUSE OF THE MICROWAVE OVEN.
Puli out the power p�ug, take off the cabinet, discharge the capacitor, measure the resistance value of the primary winding and the secondary winding of the transformer with an avometer (FIG.5 - 10 and FIG.5 - 9). The resistance value of the primary winding should be about 2.2 ohms, the secondary winding should be about 130 ohms. Otherwise, it indicates the transformer has broken, and should be replaced by a new one. If the transformer is normal, then the high voltage capacitor Fig. 5-8 should be checked. Puli out the connecting p�ug of the capacitor, and measure it with R*1 grade of an avometer, the two rods of the avometer connect the two polarity of the capacitor. When they just connected, the reading of the avometer should be zero, then increases to nine megaohm slowly. Change the rod to different polarity, the reading repeat secondary winding from zero to nine megaohm (FIG.5 - 11), it means the capacitor is normal. If the indicator of the avometer can't point out from zero to nine megaohms, it indicates the high voltage capacitor has broken, and should be replaced by a new one. If it is normal between the two pole of the capacitor, then the insulation between the capacitor pole and the cabinet should be measured with RxlOK grade of an avometer. The resistance value should be "°°" (FIG.5 - 12). If it is short circuited or have a number reading, it indicates that the capacitor has been punctured or electricity leaked, and should be replaced by a same model, same capacity one.
transformer primary winding
Fig. 5-9
Fig. 5-10
Fig. 5-12
If the resistance value of the capacitor's two pole ar� "°°" , the capacitor is normal. Then check the earth of the magnetron's two filaments to see whether they ar� short circuited (FIG.5 - 13). If they ar� short - circuited and the filament strikes the shell of the magnetron, it indicates the magnetron magnetron has broken, and should be replaced by a new, same model one. If the magnetron is also normal, then test the pilot switch. Puli out the two plugs of the switch. Measure it with the R*1 grade of avometer, the two rod connect the p�ug of the switch, the resistance value should be"°°" (FIG.5 - 8). Then press down the pilot switch with a screwdriver, if the reading of the avometer pointed to zero, it indicates the pilot switch has broken, and should replace it with a new, same