The AKAI 1720 model reel to reel tape recorder described in this Manual is quite an old unit - circa late 1960's. As a consequence, the description of the mechanical details - and adjustments thereof - is quite critical. The manual does this quite well. The schematics are also well presented and have detailed PCB overlays. Probably the only negative is that some half-tone detail has been lost from the original manual as it has been scanned in simple B&W.
LC-15B2E
[4] Lamp error detection
4-1. Functional description This LCD colour television has a function (lamp error detection) to be turned OFF automatically for safety when the lamp or lamp circuit is abnormal. If the lamp or lamp circuit is abnormal, or some other errors happen, and the lamp error detection is executed, the followings occur. 1 The main unit of television is turned OFF 5 seconds after it is turned ON. (The power LED on the front side of TV turns from green to red.) 2 If the situation 1 happens 5 times sequentially, television can not be turned ON. (The power LED remains red.) 4-2. Countermeasures 4-2-1. Check when turning OFF the lamp error detection When television is turned OFF by the lamp error detection mentioned above, it enters the adjustment process with the power LED red. Entering the adjustment process turns OFF the error detection and turns ON TV. This enables the operation check to detect errors in the lamp or lamp circuit. Check whether "ERROR NO RESET" on line 5, page 1 of the adjustment process is 1 or more. If it is 1 or more, it indicates the lamp error detection was executed. 4-2-2. Resetting of the lamp error count After confirming that the lamp or lamp circuit is normal, reset the lamp error count. Select "ERROR NO RESET" on line 5, page 1 of the adjustment process and set the number to 0 using the volume button. Page 1 of the adjustment process
1 +B� A MODE I NCH NTSC E RRO DJ L I SI ZE PW M F R Q R NO RESET 160 C2E 15 0C0 5 OFF
P MUT E
Reset 0
C2 E
VER
1. 00
Afterwards, perform the operation check to confirm that the lamp error detection does not function.