Description of SHARP LC-28HM2 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 MX-2700N SHARP Service Manual by Lloyd Parks;
Manuals were delivered promptly and were correct as advertised. No issues with the download link which was provided promptly after everything was processed. Very pleasant experience
 GF9191H/E/HB SHARP Service Manual by Roy Lang;
Paid for service manual & got the download fast - worth a visit if you need a service manual
 A501 BRAUN Service Manual by Thomas Nehls;
It's the manual, I am searching for. Now I am able to repair my Braun A501.
 PM5131 PHILIPS Service Manual by Thomas Nehls;
Great service manual. Unfortunately on page no. 41 there are some details which i can't read.
 PS-FL7II SONY Service Manual by Gerald Levitz;
Wonderful service... doubt that I could have made the repairs to my turntable without this service manual. Great help! Well worth the price paid!

Text excerpt from page 16 (click to view)
LC-28HM2
AN-28SP2

ADJUSTMENT PROCEDURES
When indicating the adjustment line in the process adjustment mode, it is described in such a manner that the second line on page 1, for example, is �P1L2�.
1. Precautions and notes for adjustment » As power source, use the stable AC power. » Note that, when the power is switched on for the first time, it takes approx. 10 seconds before the unit starts up because E2P needs to be initialized. (Both monitor side LED and AVC center side LED are lit in green, with the backlight being OFF.) Never turn off the power during this time. When restarting the system the first time after the power interruption caused by power failure, etc., execute P6L5 �CENT EEP RST S/C ONLY� for resetting before doing adjustment. » When the data has been updated in the program more than once, updating the program will not re-write the adjustment value in most cases. Any time the program has been updated, it is recommended to follow the procedure; (a) save the data of the adjusted items in memorandum, (b) initialize the EEPROM once at both AVC center and monitor, and then (c) write in the adjustment values recorded. 2. How to enter into special modes 1 Going into the process adjustment mode [Procedure] (1) Using remote controller Connect the display and the AVC center using the system cable in the specified manner. Switch on the power. After start-up, press [PROCESS ADJUSTMENT] button of the remote controller. (2) Using main unit key Connect the display and the AVC center using the system cable in the specified manner. While pressing [BRIGHTNESS] and [VOL�] buttons simultaneously, switch on the power. [Contents] Various adjustments can be made manually. 2 Going into the inspection process mode [Procedure] Go into the process adjustment. Turn P1L6 �SIGNAL INFO� to �ON�. Terminate the process adjustment mode with remote controller operation. [Contents] The bar display items such as volume and video/sound adjustments are made switching in the sequence of minimum, medium and maximum. 3 How to make presetting [Procedure] (1) When remote controller capable of outputting the �preset� code is not available Go into the process adjustment. Turn P27L1 �INDUSTRY INIT� to �ON�, and the press [ENTER] button of the remote controller. The process is finished when �/ / / / / / / / / / / / / / / / / / / / / / / / / / / / � display disappears. (2) When remote controller capable of outputting the �preset� code is available Go into the process adjustment. Press [PRESET] button of the remote controller. The process is finished when �INDUSTRY INIT NOW� display disappears. [Contents] User adjustment value can be made as default setting. The data adjusted in the process adjustment is not altered.

16

You might also want to buy

$4.99

LC28HM2 SHARP
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

LC-28HM2 SHARP
Parts Catalog

Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
>
Parse Time: 0.267 - Number of Queries: 101 - Query Time: 0.071