Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Easy to order the manual. Good quality and fast delivery.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
 ;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
<MD>
� Perform 1~3 adjustment when display showing [NO ADJUST]. 1. Temperature Compensation Adjustment � Test point: Check on the display. � Tool : Thermometer � Adjustment procedure 1) After MD test mode has started up, press "s" button to display [ALL SVOFF]. 2) Press "DISPLAY" button to display [TEMP = ]. 3) Press "T-BASS" button to display [T + ** C ± ##]. 4) Put the thermometer near the MD mechanism to measure the room temperature. 5) Adjust the indication value ** using "l" and "j" buttons until the value is the same as room temperature. Press "ENTER" button after adjusting. 6) Ptess "s" button to display [ALL SVOFF] after adjusting. 7) After adjustment is completed, once again set the display to [TMP + ** C ± ##] and check the value that has been caluculated with the addition or subtraction of the numerical values of ## in relation to the ** value. This value is to be the same sa room temperature. NOTE: Do not perform this adjustment if it is not possible to measure the room temperature.
S S
Then, confirm the values of [I ** E within the following range. [ ** ] ......................... 04~0A
S
] in the display are
[
] ......................... 09~15
5) Press "DISPLAY" button again. Confirm the values of [F ** T ## S I I] in the display are within the following range. [**] ........................... 1A~45 [##] ........................... 00~03 [I I] ........................ 00~03 6) Press "s" button to display [ALL SVOFF]. Adjustment for PIT disc 1) Insert the TGYS-1 test disc. 2) Press "s" button to display [ALL SVOFF]. 3) Press "JOG MODE" button to display [SEL PIT]. 4) When pressing "MD function" button, [AUTO ADJ] is displayed and adjustment start. After adjusting, [DONE] is displayed. (If [failed] is displayed, the adjustment failed.) 5) Press "s" button to display [ALL SVOFF]. Checking IVR, EFB and focus/tracking/sled gain of PIT disc Perform the same procedures as for MO disc and check that the display is within the range below; [IVR]..............................14~19 [EFB]..............................09~15 [FOCUS GAIN].............1A~45 [Tracking gain]...............00~3F [Sled gain]......................00~3F 4. Checking Error Rate (PIT disc) 1) Insert the TGYS-1 test disc. 2) Move the pickup to the center track using "g" or "f" buttons. 3) Press "JOG MODE" button to display [SEL PIT]. 4) Press "E" button to display [FOCUS ON]. 5) Press "ENTER" button to switch the mode to [AL SV ON]. Then press "DISPLAY" button twice to display [00 ** 000]. 6) Check the value of ** is below [30] at this time. 7) Press "s" button to display [ALL SVOFF]. 5. Checking Record/Playback Error Rate (MO disc) 1) Insert the MDW-60 test disc. 2) Move the pickup to the center track using "g" or "f" buttons. 3) Press "JOG MODE" button to display [SEL GRV]. 4) Press "MD REC" button to display [R ANALOG]. 5) Press "E" button to display [FOCUS ON]. 6) After displaying [ALL SV ON] by pressing "ENTER" button, press "SYNCRO REC" button. 7) Recording begins after OWH has moved when "MD REC" button is pressed once again. At this time, display will change from [ALL SV ON] to [A0600C ## S]. 8) Press "s" button after recording has progressed for about 15 seconds, changing the display to [ALL SVOFF]. 9) Press "MD EJECT" button to raise the OWH. 10) Press "E" button to display [FOCUS ON]. 11) Once [ALL SV ON] has been displayed by pressing "ENTER" button, press "DISPLAY" button to display [A **** C ## S]. After **** reaching 600, press "DISPLAY" button once again to display [00 // 000]. Check that the value of // is below than [20] at this time.
S S S
2. Laser Power Adjustment � Test point: Pickup laser output � Tool : Laser power meter � Adjustment procedure 1) Starting in the [ALL SVOFF] status, press "EDIT" button three times to change the display to [LA WRITE]. 2) Press "T-BASS" button once and change the display to [LASER = **]. 3) Measure the laser output of pickup with the laser power meter and adjust output by "g" or "f" buttons so that the measurement value becomes 6.8mW ± 0.03mW. Press "ENTER" button after adjusting. 4) Press "s" button to display [ALL SVOFF] after adjusting. Caution: There is a possibility that pickup may be damaged if laser output exceeds 7.0mW. 3.Auto Sequence Adjustment (EFB/IVR/FOCUS AGC/TRACKING AGC adjustment) � Test disc: MDW-60, TGYS-1 Adjustment MO disc 1) Insert the MDW-60 test disc. 2) Press "s" button to display [ALL SVOFF]. 3) Press "JOG MODE" button to display [SEL GRV]. 4) When pressing "MD function" button, [AUTO ADJ] is displayed and adjustment start. After adjusting, [DONE] is displayed. (If [FAILED] is displayed, the adjustment failed.) 5) Press "s" button to display [ALL SVOFF]. NOTE: 1.As there is a posibility that adjustment may not be able to adequately performed if the disc is dirty or scratched, make sure to keep the disc clean. 2.When using a MO disc, one section will be erased in order to change it to WRITE POWER, so a special disc is to be used. Checking for IVR, EFB and focus/tracking/sled gain of MO disc 1) Move the pickup to the center track using "g" or "f" buttons. 2) Press "E" button to display [FOCUS ON]. 3) Press "ENTER" button to switch the mode to [ALL SV ON]. 4) Press "s" button and "DISPLAY" button twice.