It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
 ;
Another excellent aquisition. Fine detailed manual. Thanks
[Charge Threshold Level Adjustment]
Mode Signal Measurement point Measuring equipment Adjustment page Adjustment address Specification value D 0E, 0F, 10, 11, 12 YYh = D8h ± 06h Power ON Any Displayed data on adj. remote commander
Connection: Referring to Fig. 2-2, connect the following equipment. (1) Connect the regulated power supply and a digital voltmeter to the battery terminal. (2) Connect the adjusting remote commander to the CN902 on YM-11 (G)/(H) board. Adjustment Procedure: (1) Adjust the output voltage of regulated power supply so that the battery terminal voltage is 7.2 Vdc. (2) Turn ON the POWER switch on the set. (3) Set data: 01 to page: 1, address: 00. (4) Set data: 01 to page: 2, address: 00. (5) Set data: 01 to page: 2, address: 2C. (6) Adjust the output voltage of regulated power supply so that the battery terminal voltage is 8.3 ± 0.02 Vdc. (7) Read data (YYh) on page: 2, address: 2D. (8) Confirm that the data (YYh) satisfies the specification value. (9) Using the following formulas (calculation of hexadecimal numbers), calculate the adjustment data and enter them to respective adjustment addresses. Address: 0E D0E = YYh + 04h Address: 0F D0F = YYh Address: 10 D10 = YYh � 5Ah Address: 11 D11 = YYh � 55h Address: 12 D12 = YYh + 09h
Note: After setting each data, be sure to press the PAUSE button on the adjusting remote commander.
(10) Set data: 00 to page: 1, address: 00. (11) Set data: 00 to page: 2, address: 00. (12) Set data: 00 to page: 2, address: 2C.
Regulated Power Supply AF OSC
Attenuator
600 �
L
Digital Voltmeter Adjusting Remote Commander CN902 J101 A/V IN YM-11 (G)/(H) Extension Cable (J-6082-291-A) Pattern Generator
R
Video Output (75 �)
Fig. 2-2