I bought the service-manual of the sony ICB-1020(an old transmitter-receiver) at "www.Owners-Manual.com", I found the service-manual for a fairly cheap price(in comparison with other sellers). I filled in some questions, payed the order with Ideal, and within 24 hours I had my service manual. I was very happy:In no time I had my service-manual and everything, but literally everything was noted down in the manual; the electronic scheme, the parts list, etcetera.
A very practical, reference-document.
 ;
This comprehesive service maual was greatly appreciated, as was the digital download.
 ;
Good en helpfull black and white scanned Srfvice manual of the Philps D8444. Quick service and delivery
 ;
Scan was really good quality, easy to read, download easy
 ;
very good manual as always. easy to read, detailed and includes schematic
LZ-800W
ADJUSTMENT
X35 Gamma Timing Controller Circuit Adjustment Specification
Item 5. Gamma curve adjustment Power Supply Voltage: 14.4V Adjustment method/Adjustment value Conditions (6) Adjust GAMMA2 VR305 so the 7th step from the pedestal is 3.1V±0.1V. � Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV 4.0V 3.1V
(7) Adjust BLACK adjustment VR300 so the 3rd step from the pedestal is maximized.
4.0V MAX (8) Adjust CONTRAST adjustment VR304 so the 11th step from the pedestal is 3.7V±0.1V.
� Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV
4.0V
� Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV
3.7V
6. VCOM amplitude adjustment (COM-AC)
� Adjust COMAC VR303 so that the VCOM amplitude is as shown in the diagram below. 8.5V±0.1V 8.5V
� Input signal Composite input (10 step signal) � Set to AC range � 2V/DIV
7. VCOM center adjustment (COM-DC)
� Adjust COMDC VR302 so that the VCOM waveform is as shown in the diagram below. 1.5V±0.5V 1.5V GND
� Input signal Composite input (10 step signal) � Set to DC range
�The flicker adjustment is done with the main unit procedure.
14
|