Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
 ;
5 STARS for FAST DELIVERY, BEST PRICES and QUALITY PRODUCT. Item was exactly as described with superb resolution. Will definitely source all my future requirements from this website. Thanks a lot owner-manual.com!
 ;
OEM manual provided all schematics, board layouts and component specs necessary to facilitate unit maintenance. All pages were clear and readable.
 ;
Good condition and quality. Hard to find anywhere in Internet, only on this site.
 ;
Exactly what I needed to be able to bring the amp back to life... will come back to this site the next time I need schematics.
LZ-800W
ADJUSTMENT
X35 Gamma Timing Controller Circuit Adjustment Specification
Item 5. Gamma curve adjustment Power Supply Voltage: 14.4V Adjustment method/Adjustment value Conditions (6) Adjust GAMMA2 VR305 so the 7th step from the pedestal is 3.1V±0.1V. � Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV 4.0V 3.1V
(7) Adjust BLACK adjustment VR300 so the 3rd step from the pedestal is maximized.
4.0V MAX (8) Adjust CONTRAST adjustment VR304 so the 11th step from the pedestal is 3.7V±0.1V.
� Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV
4.0V
� Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV
3.7V
6. VCOM amplitude adjustment (COM-AC)
� Adjust COMAC VR303 so that the VCOM amplitude is as shown in the diagram below. 8.5V±0.1V 8.5V
� Input signal Composite input (10 step signal) � Set to AC range � 2V/DIV
7. VCOM center adjustment (COM-DC)
� Adjust COMDC VR302 so that the VCOM waveform is as shown in the diagram below. 1.5V±0.5V 1.5V GND
� Input signal Composite input (10 step signal) � Set to DC range
�The flicker adjustment is done with the main unit procedure.