Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
very helpfull
circuit diagram and sparepart list available
 ;
Very good reproduction (copy) of original manual. Didn't have a parts list, but schematic was completely labeled with parts. Complete instructions on how to adjust mechanical functions of the 8-track deck. Well worth having and at a very reasonable cost.
 ;
It's a full manual. All the parts are in there. I haven't found the problem yett, but I am working on it; hope I can rebuild the part myself. To make it more secure and unbreakable this time. Because the part has failed several times before and costs a lot to let it be repaired.
Thanks so much for this rich illustrated and parted manual.
 ;
I downloaded the document. The manual was complete, well scanned and everything was legible. I could zoom in see what I needed to know. There's not much more that you can ask.
 ;
It was complete service manual with all needed service informations. Thanks.
LZ-800W
ADJUSTMENT
X35 Gamma Timing Controller Circuit Adjustment Specification
Item 5. Gamma curve adjustment Power Supply Voltage: 14.4V Adjustment method/Adjustment value Conditions (6) Adjust GAMMA2 VR305 so the 7th step from the pedestal is 3.1V±0.1V. � Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV 4.0V 3.1V
(7) Adjust BLACK adjustment VR300 so the 3rd step from the pedestal is maximized.
4.0V MAX (8) Adjust CONTRAST adjustment VR304 so the 11th step from the pedestal is 3.7V±0.1V.
� Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV
4.0V
� Input signal Composite input (10 step signal) � Set to AC range � Oscilloscope 0.5V/DIV
3.7V
6. VCOM amplitude adjustment (COM-AC)
� Adjust COMAC VR303 so that the VCOM amplitude is as shown in the diagram below. 8.5V±0.1V 8.5V
� Input signal Composite input (10 step signal) � Set to AC range � 2V/DIV
7. VCOM center adjustment (COM-DC)
� Adjust COMDC VR302 so that the VCOM waveform is as shown in the diagram below. 1.5V±0.5V 1.5V GND
� Input signal Composite input (10 step signal) � Set to DC range
�The flicker adjustment is done with the main unit procedure.