Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The purchased manual is an high-quality scan of the original JVC paper-based Service Manual. The Service Manual includes the Owner´s Manual, so you do not have to buy both of them.
 ;
It paid to find this Service Manual, couldn't find it anywhere else. Exactly what I wanted. Received within 24 hours.
 ;
Complete manual with clear schematic diagrams and printed circuit board layouts of two variants of the headset and the transmitter an old and a new version.
Also shows how the headset and the transmitter is opened and how transmitter and receivers can be adjusted and where to measure.
I had no problems to repair the headset using this service manual.
 ;
Excellent printing quality. A complete and very useful manual with all details.
 ;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
Alignment and Adjustments
1-2 Cassette Deck
1-2-1 To Adjust Tape Speed
Notes * Measuring tape: i) MTT-111 CN(or equivalent) (Tapes recorded with 3kHz) ii) MTT-5512 (or equivalent)
output Speaker Terminal Frequency Counter
VTVM
Cassette Deck
SP2 SPEAKER
Oscilloscope
SET VH (GND)
In Out Figure 1-5
- Adjust SPEED Control Step Item SPEED Control Tape MTT-111N (3KHZ) PreSetup
Press play button after puting tape into the Deck1
Figure 1-4
Adjust Point SVR3
Standard
Figure
Remark A&B Deck deviation : 60Hz
1
3 kHZ ±1%
Fig. 1-4
Recording /Play head
2
HI SPEED Control
MTT-111 (3KHZ)
Press play button after puting tape into the Deck1
No Adjustment
-
Fig. 1-4
5200~6600Hz Check
AZIMUTH control Figure 1-6
- Adjust Record Frequency Step 1 Item Tape PreSetup
Press Rec button after connecting (Fig1-5) Press Rec button after connecting (Fig1-5)
Adjust Point SVR4 SFT1
Frequency Range ±5dB
60KHZ±1KHZ(MAX900) 85KHZ±1KHZ(MAX920)
Figure Fig. 1-5
Remark SPEAKER VTVM (A-DECK) SP2
L,R MTT-112B Unbalance (1KHZ) Record Frequency MTT-5512
2
Fig. 1-5
- Adjust Azimuth PreSetup
Press Play button after puting tape into the Deck1
Step
Item
Tape
Adjust Point Adjustment screw of HEAD
Standard Figure
Remark
1
Azimuth
MTT-111CN
8KHZ
Fig.1-4 Fig. 1-6
Output:Maximum
- Adjust Rec Bias Voltage(Only MAX920 Model) Step Item Rec Bias Voltage Tape MTT-5512 (3KHZ) PreSetup
Press Rec button after puting tape into the Deck1
Adjust Point SVR1 SVR2
Votage Range 7V±0.5V
Remark Connete to MWF6 from AC Meter.
1
2-2