It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
 ;
Another excellent aquisition. Fine detailed manual. Thanks
 ;
Good quality for the scan, complete, but as usual for Tascam, not so comprehensive !
 ;
great manual readable & easy to downlaod to be recommanded
Alignment and Adjustments
1-2 Cassette Deck
1-2-1 To Adjust Tape Speed
Notes * Measuring tape: i) MTT-111 CN(or equivalent) (Tapes recorded with 3kHz) ii) MTT-5512 (or equivalent)
output Speaker Terminal Frequency Counter
VTVM
Cassette Deck
SP2 SPEAKER
Oscilloscope
SET VH (GND)
In Out Figure 1-5
- Adjust SPEED Control Step Item SPEED Control Tape MTT-111N (3KHZ) PreSetup
Press play button after puting tape into the Deck1
Figure 1-4
Adjust Point SVR3
Standard
Figure
Remark A&B Deck deviation : 60Hz
1
3 kHZ ±1%
Fig. 1-4
Recording /Play head
2
HI SPEED Control
MTT-111 (3KHZ)
Press play button after puting tape into the Deck1
No Adjustment
-
Fig. 1-4
5200~6600Hz Check
AZIMUTH control Figure 1-6
- Adjust Record Frequency Step 1 Item Tape PreSetup
Press Rec button after connecting (Fig1-5) Press Rec button after connecting (Fig1-5)
Adjust Point SVR4 SFT1
Frequency Range ±5dB
60KHZ±1KHZ(MAX900) 85KHZ±1KHZ(MAX920)
Figure Fig. 1-5
Remark SPEAKER VTVM (A-DECK) SP2
L,R MTT-112B Unbalance (1KHZ) Record Frequency MTT-5512
2
Fig. 1-5
- Adjust Azimuth PreSetup
Press Play button after puting tape into the Deck1
Step
Item
Tape
Adjust Point Adjustment screw of HEAD
Standard Figure
Remark
1
Azimuth
MTT-111CN
8KHZ
Fig.1-4 Fig. 1-6
Output:Maximum
- Adjust Rec Bias Voltage(Only MAX920 Model) Step Item Rec Bias Voltage Tape MTT-5512 (3KHZ) PreSetup
Press Rec button after puting tape into the Deck1
Adjust Point SVR1 SVR2
Votage Range 7V±0.5V
Remark Connete to MWF6 from AC Meter.
1
2-2