This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
 ;
This service manual includes drawings, schematics, exploded views, parts list, operating details, and more. Very good scans, very readable. The only thing that made it a 4 star rating was on approximately 4 scans only half of the page was scanned then the other half. I would have preferred the pages to be whole scans.
 ;
Good manual contains all it takes to update, repair,these types of mixers.Thanks.
 ;
Great service. Fast response. High quality scan. Good price.
Thank you very much!!!
Oleg S.
Alignment and Adjustments
1-2 Cassette Deck
1-2-1 To Adjust Tape Speed
Notes * Measuring tape: i) MTT-111 (or equivalent) (Tapes recorded with 3kHz) ii) MTT-5512 (or equivalent)
- Adjust SPEED Control Step Item SPEED Control Tape MTT-111N (3KHZ) PreSetup
Press play button after puting tape into the Deck1
Adjust Point
UVR2(COMMON) DVR3(Only MAX909/910/916)
Standard 3 kHZ ±1% 3 kHZ ±1%
Figure Fig. 1-5 Fig. 1-5
Remark
Front PCB Main PCB
5200~6600Hz Check
1
2
HI SPEED Control
MTT-111 (3KHZ)
No Adjustment
-
Fig. 1-5
- Adjust Record Frequency Step 1 Item L,R Unbalance Record Frequency Tape MTT-112B (1KHZ) MTT-5512
Press Rec button after connecting (Fig1-6)
PreSetup
Adjust Point DVR4
Frequency Range ±0.5dB
60KHZ±1KHZ (Only MAX909/910/916) 85KHZ±1KHZ(COMMON)
Figure Fig. 1-6
Remark SPEAKER VTVM (A-DECK) DCW4
2
DL4
Fig. 1-6
- Adjust Azimuth Step Item Tape PreSetup Adjust Point Adjustment screw of HEAD Standard Figure Remark
1
Azimuth
MTT-113CN
8KHZ
Fig. 1-7
Output:Maximum
- Adjust Rec Bias Voltage Step Item Rec Bias Voltage Tape MTT-5512 (3KHZ) PreSetup Adjust Point SVR1 SVR2 Votage Range 7V±0.5V Remark Connect to MWF6 from AC Meter.
1
Fig1-8. Adjustment location of Deck Part
2-2 Samsung Electronics
|
|
 |
> |
|