Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
;
The service manual is a good quality scan of the Panasonic NV-850, which is electrically identical to the Philips VR 6920, but mecanically just nearly.
Alignment and Adjustments
1-2 Cassette Deck
1-2-1 To Adjust Tape Speed
Notes * Measuring tape: i) MTT-111 (or equivalent) (Tapes recorded with 3kHz) ii) MTT-5512 (or equivalent)
- Adjust SPEED Control Step Item SPEED Control Tape MTT-111N (3KHZ) PreSetup
Press play button after puting tape into the Deck1
Adjust Point
UVR2(COMMON) DVR3(Only MAX909/910/916)
Standard 3 kHZ ±1% 3 kHZ ±1%
Figure Fig. 1-5 Fig. 1-5
Remark
Front PCB Main PCB
5200~6600Hz Check
1
2
HI SPEED Control
MTT-111 (3KHZ)
No Adjustment
-
Fig. 1-5
- Adjust Record Frequency Step 1 Item L,R Unbalance Record Frequency Tape MTT-112B (1KHZ) MTT-5512
Press Rec button after connecting (Fig1-6)
PreSetup
Adjust Point DVR4
Frequency Range ±0.5dB
60KHZ±1KHZ (Only MAX909/910/916) 85KHZ±1KHZ(COMMON)
Figure Fig. 1-6
Remark SPEAKER VTVM (A-DECK) DCW4
2
DL4
Fig. 1-6
- Adjust Azimuth Step Item Tape PreSetup Adjust Point Adjustment screw of HEAD Standard Figure Remark
1
Azimuth
MTT-113CN
8KHZ
Fig. 1-7
Output:Maximum
- Adjust Rec Bias Voltage Step Item Rec Bias Voltage Tape MTT-5512 (3KHZ) PreSetup Adjust Point SVR1 SVR2 Votage Range 7V±0.5V Remark Connect to MWF6 from AC Meter.
1
Fig1-8. Adjustment location of Deck Part
2-2 Samsung Electronics
|
|
|
> |
|