Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
 ;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
 ;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
 ;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
 ;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
Alignment and Adjustments
1-2 Cassette Deck
1-2-1 To Adjust Tape Speed
Notes * Measuring tape: i) MTT-111 (or equivalent) (Tapes recorded with 3kHz) ii) MTT-5512 (or equivalent)
- Adjust SPEED Control Step Item SPEED Control Tape MTT-111N (3KHZ) PreSetup
Press play button after puting tape into the Deck1
Adjust Point
UVR2(COMMON) DVR3(Only MAX909/910/916)
Standard 3 kHZ ±1% 3 kHZ ±1%
Figure Fig. 1-5 Fig. 1-5
Remark
Front PCB Main PCB
5200~6600Hz Check
1
2
HI SPEED Control
MTT-111 (3KHZ)
No Adjustment
-
Fig. 1-5
- Adjust Record Frequency Step 1 Item L,R Unbalance Record Frequency Tape MTT-112B (1KHZ) MTT-5512
Press Rec button after connecting (Fig1-6)
PreSetup
Adjust Point DVR4
Frequency Range ±0.5dB
60KHZ±1KHZ (Only MAX909/910/916) 85KHZ±1KHZ(COMMON)
Figure Fig. 1-6
Remark SPEAKER VTVM (A-DECK) DCW4
2
DL4
Fig. 1-6
- Adjust Azimuth Step Item Tape PreSetup Adjust Point Adjustment screw of HEAD Standard Figure Remark
1
Azimuth
MTT-113CN
8KHZ
Fig. 1-7
Output:Maximum
- Adjust Rec Bias Voltage Step Item Rec Bias Voltage Tape MTT-5512 (3KHZ) PreSetup Adjust Point SVR1 SVR2 Votage Range 7V±0.5V Remark Connect to MWF6 from AC Meter.
1
Fig1-8. Adjustment location of Deck Part