Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
- Very good scan quality, PERFECT!
- Sehr gute scan Qualitaet, empfehlenswert!
Wolfgang Sundhaus
 ;
Good site, works ok and you get what you order, no problems experienced, got my manual within a day. A++++
 ;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
 ;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
 ;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
Alignment and Adjustments
1-2 Cassette Deck
1-2-1 To Adjust Tape Speed
Notes 1) Measuring tape: i)(Tapes recorded with 3kHz) MTT-111 (or equivalent) ii) MTT-5512 (or equivalent) 2) Connect the cassette deck to the frequency counter as in figure 1-4.
SPK OUT output Figure 1-4 Cassette Deck Frequency Counter
1-2-2 To Adjust PlayBack Level
Notes 1) Before the actual adjustment, clean the play/recording head. 2) Measuring tape : i) MTT-114(or equivalent 10kHz AZIMUTH control) ii) MTT-112(or equivalent) : 3) The cassette deck is connections as shown in figure 1-6.
Recording /Play head
AZIMUTH control screw Figure 1-5
SET
SPK OUT
VTVM
Oscilloscope
Step
Item
Pre-Setup Condition OUT
Pre-Setup 1) Deck 1:MTT-111 2) Press PLAY SW button 3) Deck 2:MTT-5512
To Adjust
Standard
Remark
(GND)
! Adjust Deck 1 Play Level
Turn URV1 to left and right FRONT PCB 3KHz Step Item Pre-Setup Condition SPK OUT (VTVM is 1 AZIMUTH connected to the scope) Pre-Setup After putting MTT114 into Deck 1 1)Press PLAY button. To Adjust
Figure 1-6
In Out
1
NOR SPEED Control
(connected to the frequency counter)
Standard Max output and same phase (both channels)
Remark After adjustment secure it with REGION LOCK.
1) Turn the control screw to as shown in Figure 1-5.
Adjust REC Bias Voltage
Step Item REC Bias Voltage Pre-Setup Condition Connect to DCW2 as in Fig.1-7 and read the VTVM. Pre-Setup Input MTT-5512 into Deck2,then press REC button. To Adjust L-CH;DSR2 and R-CH;DSR1 to the right and left. Standard Remark See diagram for adjustment location
@ Adjust Deck 2 Play Level
Step 1 Item AZIMUTH Pre-Setup Condition SPK OUT (VTVM is connected to the scope) Pre-Setup After putting MTT114 into Deck 2 1)Press PLAY button. To Adjust 1) Turn the control screw to as shown in Figure 1-5. Standard Max output and same phase (both channels) Remark After adjustment secure it with REGION LOCK.
1
6V
VTVM SET
Oscilloscope
IN
UCW2
Figure 1-7 Samsung Electronics 1-3
|
|
 |
> |
|