PDF Contains
Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217.
It is the actual Service Manual for SQ10
 ;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
 ;
Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit.
regards: Nick
 ;
This was super service.Ordered this manual and was reading the download an hour later
MC-E601 / MC-E603
8 TROUBLE SHOOTING GUIDE
CONDITION CHECKPOINT Motor fails to rotate. Power cord connection (no noise is heard at all). Motor continuity METHOD OF INSPECTION Check power cord continuity between plug pins and contact base. Check motor continuity between carbon brush holder tabs. Carbon brushes Check if there is gap between carbon brush and conmutator. ON/OFF Switch Check continuity across switch connections. Thermal cut-out Check continuity across thermal cutout tabs. Triac Check if the triac is in open circuit. Power control circuit Check if the diac is in open circuit. Rotating potentiometer (VR2) Check if the potentiometer is in open circuit. Trimmer potentiometer (VR1) Place the rotating potentiometer at min. power and check if the potentiometer (VR1) is adjusted at 450W. Motor runs but does Hose or Suction inlet Check if there is any blockage in the not suction. hose or suction inlet. Dust bag / Central filter Check if dust bag is full or dust accumulated in central filter. Noise or vibration. Motor fan Check dust accumulated in motor fan (it could happen if the vacuum cleaner has been used with a broken bag or without central filter). Motor does not Rotating potentiometer Check if the potentiometer is shortchange power. circuited. (Runs always at full speed). Power control circuit Check if the power control circuit is short-circuited. Motor runs Rotating potentiometer Check possible bad contact of the irregularly. rotating potentiometer PCB tracks. CAUSE / REMEDY If there is no continuity, replace the power cord. If there is no continuity, replace the motor. If there is gap between carbon brush and conmutator, replace both carbon brushes. If there is no continuity, replace power control circuit. If there is no continuity, replace thermal cut-out. If it is in open circuit, replace power control circuit. If it is in open circuit, replace power control circuit. If it is in open circuit, replace power control circuit. If it is adjusted at 450W and the motor doesn�t work, replace power control circuit. If there is any blockage, remove it. If the paper bag is full, replace it. If the central filter is dirty, clean or replace it. If there is dust accumulated in motor fan, replace the motor and check filter condition. (never try to dismantle the motor fan). If it is short-circuited, power control circuit.
If it is short-circuited, replace it. If there is bad contact, replace power control circuit.