Who's Online
There currently are 6042 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a high quality manual with clear schematic and components layout diagrams ; with service procedure included.
;
This service manual for the Kenwood KT-990D was reproduced really well ,is very legible and manual is complete.Combined with the low price paid,in the future,I will be checking Owner-Manuals.com any time I need a manual.
;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
MC-GG283-00
3 REPLACEMENT INSTRUCTIONS
3.1.
3.1.1.
Lower Plate
Removal
1. Place handle in low position. 2. Turn the vacuum cleaner over exposing the underside. Release the lower plate by pressing the two (2) latches that secure it inward. 3. Separate the lower plate from the vacuum.
2. Remove the lower plate as outline in Lower Plate remove / installation section.
3.1.2.
place.
Installation
3. Carefully lift up on the agitator assembly until it clear both sides of the nozzle housing.
1. Hook the front of the lower plate into the slots on the front of the nozzle housing. Press the lower plate down into 2. Fasten the lower plate by pushing the two (2) latches outward. NOTE: For general servicing, it is necessary to eliminate pinching of any wire during reassembly. After servicing any electrical component or enclosure, the unit should be reassembled and checked for dielectric breakdown or current leakage.
3.2.
3.2.1.
Agitator Assembly
Removal
4. Remove the belt from the motor shaft by sliding it off between the end of the shaft and the nozzle housing.
1. The brushes are not replaceable separately. When the brushes need replacing, the agitator assembly will have to be replaced.
3.2.2.
Installation
1. Place the belt around the motor shaft.