Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Exactly the JVC service manual and schematics that I was looking for - delivered just hours after order. Will do business again!
 ;
This is a fantastic site, ad I have been a returning satisfied cusumer!
Thanx for a great sevice!
 ;
Je suis audiophile belge, électronicien et créateur d'enceintes acoustiques.
J'ai apprécié la qualité des documents fournis. Ils sont très lisibles, ils peuvent être agrandis sans problème et ils sont complets. Pour moi, c'est parfait. Pour cette qualité, je suis d'accord de payer. Et le système de paiement et d'envoi est simple. Merci, continuez comme cela.
Frédéric
 ;
The cover page was a little scary, very dark but readable. The remainder of the document was better copy and easily readable. Why would I give 5 Stars? (1) PRICE, (2) AUTHENTICITY, It was the real deal, filled with service information, including the specific information I required. (3) PRIVACY, I didn't start to get slammed with spam. (4) EASY TRANSACTION. Painless. (5) COMPLETE, I have found several manuals here, that I could find nowhere else. (6) I will be a repeat customer!
 ;
Well done!!! I found what I need to have, indeed!
Furthermore, due to my hobby is repairing vintage equipments, I added this web site in my desk toolbar because I have in mind to search further service manuals. Thanks a lot www.owner-manuals.com !
Regards, Maurizio
ELECTRICAL ADJUSTMENTS
2-4: WHITE BALANCE NOTE: Adjust after performing CUT OFF adjustment. 1. Place the set with Aging Test for more than 15 minutes. 2-8: VERTICAL LINEARITY NOTE: Adjust after performing adjustments in section 2-7. After the adjustment of Vertical Linearity, reconfirm the Vertical Position and Vertical Size adjustments. 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (09) on the remote control to select "VLIN". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on upside and downside becomes minimum. 2-9: SEPARATION Please do the method (1) or method (2) adjustment. Method (1) 1. Set the multi-sound signal generator for each different Lch and R-ch frequency (Ex. L-ch=2KHz, R-ch=400Hz) 2. 3. 4. and receive the RF signal. Connect the oscilloscope to the Audio Out Jack. Press the AUDIO button on the remote control to set to the stereo mode. Activate the adjustment mode display of Fig. 1-1 and press the channel button (64) on the remote control to select �SEPAL�. Press the VOL. UP/DOWN button on the remote control to adjust it until the audio output wave becomes a fine sine wave. Press the CH UP button 1 time to set to "SEPAH" mode. Press the VOL. UP/DOWN button on the remote control to adjust it until the audio output wave becomes a fine sine wave.
2. Receive the gray scale pattern from the Pattern Generator. 3. Using the remote control, set the brightness and contrast to normal position. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (16) on the remote control to select "G DRIVE". 5. Press the CH. UP/DOWN button on the remote control to select the "R CUT OFF", "G CUT OFF", "B CUT OFF", "R DRIVE" or "B DRIVE". 6. Adjust the VOL. UP/DOWN button on the remote control to whiten the R CUT OFF, G CUT OFF, B CUT OFF, R DRIVE, and B DRIVE at each step tone sections equally. 7. Perform the above adjustments 5 and 6 until the white color is looked like a white. 2-5: HORIZONTAL POSITION 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (04) on the remote control to select "HPOSI". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-6: VERTICAL POSITION 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (08) on the remote control to select "VPOSI". 4. Check if the step No. V POSI is "03". 5. Adjust the VR401 until the horizontal line becomes fit to notch of the shadow mask. 2-7: VERTICAL SIZE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (07) on the remote control to select "VSIZE". 4. Press the VOL. UP/DOWN button on the remote control until the Up/Down OVER SCAN Quantity becomes equal to the Right/Left OVER SCAN Quantity. 5. Receive a broadcast and check if the picture is normal.
5.
6. 7.
Method (2) 1. Set the multi-sound signal generator L-ch=1KHz, R-ch =Non input and receive the RF signal. 2. Connect the oscilloscope to the Audio Out Jack (R-ch). 3. Press the AUDIO button on the remote control to set to the stereo mode. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (64) on the remote control to select �SEPAL�. 5. Press the VOL. UP/DOWN button on the remote control to adjust it until the R-ch output becomes minimum. 6. Press the CH UP button 1 time to set to "SEPAH" mode. 7. Press the VOL. UP/DOWN button on the remote control to adjust it until the R-ch output becomes minimum. 8. Set the multi-sound signal generator L-ch=Non input, R-ch=1KHz and receive the RF signal. 9. Connect the oscilloscope to the Audio Out Jack (L-ch). Then perform the above adjustments 3~7.