I AM HIGHLY IMPRESSED BY THE EASE OF USE OF THIS DOWNLOAD SERVICE. INSTRUCTIONS ARE CLEAR AND SIMPLE TO FOLLOW....EVEN BY TECHNOPHOBES SUCH AS MYSELF. THE EMAILS POINT YOU IN THE RIGHT DIRECTION...ITS SO EASY PEASY. THE DOWNLOAD CHOICE OF USER MANUALS IS EXTENSIVE AND I COULD NOT FIND A CHEAPER OR MORE EFFICIENT SERVICE ON THE INTERNET. I COULD NOT HAVE MADE A BETTER CHOICE OF INFORMATION PROVIDER. SHOULD I EVER NEED ANOTHER USER MANUAL, THEN THIS IS THE FIRST CHOICE SITE. COULD NOT BE BETTER PLEASED!!!!!!!...MANY THANXES FROM JIM BURNS
PL12-Program Location
Enter Amount for Additional Time This location determines the amount needed to add more time to a dry cycle. The amount for additional time is programmable from a minimum of 0.05 to a maximum of 25.00 adjustable in 0.01 increments.
PL13-Program Location
Enter Prepurge Time 0 to 25-seconds When the Phase 7 controller detects the need for heat, it will wait for this prepurge time to expire before actually sending the signal for the heat to turn on. Enter DSI Purge Time 0 to 25-seconds After the controller sends the heat signal, the controller will wait for the direct spark ignition (DSI) purge time to expire before it checks to see if the gas valve return signal is present. Enter DSI Proof Time 0 to 20-seconds After the controller receives a gas valve signal within the DSI purge time, the controller will begin a DSI proof timer. After the DSI proof time has expired, the controller will recheck for the gas signal. Enter Buzz Time 1 to 9 beeps If the buzzer mode is set to �ON�, this location determines how many times the buzzer will beep at the end of an Anti-Wrinkle cycle. Enter Pause Time 0 to 3 minutes If the pause button is pressed and the main door is open, the controller will wait for the pause time defined in this setting to expire. Once the time has expired, the controller will begin to count down the dry time. If the pause button is not pressed prior to opening the door, the controller will not wait for the pause time before counting down the dry time.
PL14-Program Location
Enter Lint Cleaning Frequency 0 to 10 hours This feature monitors the hours of drying time and compares it with the Lint Cleaning Frequency setting in PL14. Once the lint cleaning frequency time has been met, the controller will begin prompting the user to clean the lint drawer. The controller will allow two (2) more hours of drying time before locking out the controller. The controller will not respond until after the lint drawer has been cleaned out. When the lint drawer is opened, the display will read �LINT ACCESS OPEN,� and when the lint drawer is closed, the controller will go back to a ready state and will read �Ready, Insert 25¢ to Start� (NOTE: The lint access must be opened for 5-seconds or more for the reset to occur). Enter Retry Count 0 to 2 This count is used to determine how many ignition attempts are allowed if an ignition attempt is unsuccessful. This counter increments when the heat output engages and the valve signal is lost after the trial for ignition period expires. This counter also will automatically reset once an ignition attempt is successful. The retry count range is from 0 to 2.