Who's Online
There currently are 5942 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Happy to find finally a schematic for this amplifier. The schematic is of good quality, the pcb layout is useless: all is black. Never the less, it is very easy to find the components on the board using the schematics.
;
Hard to find manual was ready the next day. Scans were very legible (including schematics). All the essential parts of the service manual were present (adjustment procedure, schematics, and parts list). It would have been nice if the rest of the manual was included (disassembly procedure, theory of operation, etc.).
;
The Service Manual for the Kenwood KR-V55R provided by owner-manuals.com was as described/advertised. The contents provided the necessary information to effect a diagnosis of the unit. The schematics above all else was instrumental in tracing the the signal flow from component to component.
;
This manual was the factory original. Excellent value and contained all the details I needed. Easy dowwnload provided the information when I needed it.
;
Impeccable, document très complet. Perfect, i get all i need. All schematic are correct. Thanks
MD-MT270H
SAFETY PRECAUTION FOR SERVICE MANUAL
Precaution to be taken when replacing and servicing the Laser Pickup. THE AEL (ACCESSIBLE EMISSION LEVEL) OF THE LASER POWER OUTPUT IS LESS THAN CLASS 1 BUT THE LASER COMPONENT IS CAPABLE OF EMITTING RADIATION EXCEEDING THE LIMIT FOR CLASS 1. THEREFORE IT IS IMPORTANT THAT THE FOLLOWING PRECAUTIONS ARE OBSERVED DURING SERVICING TO PROTECT YOUR EYES AGAINST EXPOSURE TO THE LASER BEAM. (1) When the cabinet has been removed, the power is turned on without a compact disc, and the Pickup is on a position outer than the lead-in position, the Laser will light for several seconds to detect a disc. Do not look into the Pickup Lens. (2) The Laser Power Output of the Pickup inside the unit and replacement service parts have already been adjusted prior to shipping. (3) No adjustment to the Laser Power should be attempted when replacing or servicing the Pickup. (4) Under no circumstances look directly into the Pickup Lens at any time. (5) CAUTION - Use of controls or adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure. English: This product is classified as a CLASS 1 LASER PRODUCT. German: Dieses Produkt ist ein Laserprodukt der Klasse 1. French: Ce Produit est Classifié comme étant un PRODUCTO LASER DE CLASSE 1.
Laser Diode Properties Material: GaAlAs Wavelength: 785 nm Pulse time: Read mode: 0.8 mW Continuous Write mode: max 10 mW 0.5S min cycle 1.5S Repetition
VARO ! VARNING!
Avattaessa ja suojalukitus ohitettaessa olet alttiina näkymättömälle lasersäteilylle. �lä katso säteeseen. Osynlig laserstralning när denna del är öppnad och spärren är urkopplad. Betrakta ej strälen.
Precaution to be taken when replacing and servicing the laser pickup. The following precautions must be observed during servicing to protect your eyes against exposure to the laser. Warning of possible eye damage when repairing: If the AC adaptor or batteries are connected when the top housing (disc cover) of the unit is removed, and the PLAY key is pressed, the laser will light up during focus access (2-3 seconds). (Fig. 2-1) During the operation, the laser will leak from the opening between the magnetic head and the mechanical chassis (Fig. 2-2). In order to protect your eyes, you must not look at the laser during repair. Before repairing be sure to disconnect the AC adaptor and remove the batteries.
Magnet head
,,, ,,,
Main PWB Spindle motor
Bottom Cabinet
Mechanism Chassis
Magnet Head Laser Beam
Optical pickup
Optical Pick-Up
Figure 2-1 �2�
Figure 2-2
|
|
|
> |
|