Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> SONY >> MDSPC3 Service Manual
 
 0 item(s) in your cart 

SONY MDSPC3
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of SONY MDSPC3 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 CT32L8G PANASONIC Service Manual by Matteo Vannini;
It is wonderful done!!! a great job in scanning the manual. Superior quality in all the electric scheme. Very understandable and net!!! Thank you!
 PROFIL 3563Z LOEWE Service Manual by jorge garcia;
muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
 KV29C5E SONY Service Manual by jorge garcia;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 PM3216 PHILIPS Service Manual by Ivan Semyonov;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope. All presented copies have high-resolution, so you can view all in detail. This manual will very useful for simple owners and for repairers. I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating). Also, these document is an example of excellent design of technical documentation.
 GR-AX900U JVC Service Manual by Stephane Pouliot;
Excellent printing quality. A complete and very usefull service manual with all details. GREAT SERVICE AT VERY LOW PRICE! A+++++++++++++++++++++++++

Text excerpt from page 30 (click to view)
5-7. INITIAL SETTING OF ADJUSTMENT VALUE
Note: Mode which sets the adjustment results recorded in the non-volatile memory to the initial setting value. However the results of the temperature compensation offset adjustment will not change to the initial setting value. If initial setting is performed, perform all adjustments again excluding the temperature compensation offset adjustment. For details of the initial setting, refer to �5-4. Precautions for Adjustments� and execute the initial setting before the adjustment as required. Setting Procedure : 1. Rotate the AMS knob to display �ADJ CLEAR� (C28). 2. Press the @/1 button. �Complete!� will be displayed momentarily and initial setting will be executed, after which �ADJ CLEAR� (C28) will be displayed.

5-9. TEMPERATURE COMPENSATION OFFSET ADJUTMENT
Save the temperature data at that time in the non-volatile memory as 25 �C reference data. Note : 1. Usually, do not perform this adjustment. 2. Perform this adjustment in an ambient temperature of 22 �C to 28 �C. Perform it immediately after the power is turned on when the internal temperature of the unit is the same as the ambient temperature of 22 �C to 28 �C. 3. When D101 has been replaced, perform this adjustment after the temperature of this part has become the ambient temperature. Adjusting Procedure : 1. Rotate the AMS knob and display �TEMP ADJUST� (C03). 2. Press the @/1 button and select the �TEMP ADJUST� (C03) mode. 3. �TEMP = [OK]� and the current temperature data will be displayed. 4. To save the data, press the @/1 button. When not saving the data, press the x/Z button. 5. When the @/1 button is pressed, �TEMP = SAVE� will be displayed and turned back to �TEMP ADJUST� (C03) display then. When the x/Z button is pressed, �TEMP ADJUST� (C03) will be displayed immediatelly. Specified Value : The �TEMP = � should be within �E0 - EF�, �F0 - FF�, �00 0F�, �10 - 1F� and �20 - 2F�.

5-8. RECORDING AND DISPLAYING Iop INFORMATION
The Iop (C28) data can be recorded in the non-volatile memory. Iop value on the label of the optical pick-up and Iop value after the adjustment will be recorded. Recording these data eliminates the need to read the label on the optical pick-up. Recording Procedure : 1. While pressing the AMS knob and x/Z button, connect the power plug to the outlet, and release the AMS knob and x/Z button. 2. Rotate the AMS knob to display �[Service]�, and press the @/1 button. 3. Rotate the AMS knob to display �Iop Write� (C05), and press the @/1 button. 4. The display becomes Ref=@@@.@ (@ is an arbitrary number) and the numbers which can be changed will blink. 5. Input Iop value written on the optical pick-up. To select the number : Rotate the AMS knob. To select the digit : Press the AMS knob 6. When the @/1 button is pressed, the display becomes �Measu=@@@.@� (@ is an arbitrary number). 7. As the adjustment results are recorded for the 6 value. Leave it as it is and press the @/1 button. 8. �Complete! !� will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become �Iop Write� (C05). Display Procedure : 1. Rotate the AMS knob to display �Iop Read� (C26). 2. �@@.@/##.#� is displayed and the recorded contents are displayed. @@.@ indicates Iop value labeled on the pick-up. ##.# indicates Iop value after adjustment 3. To end, press the x/Z button to display �Iop Read� (C26).

5-10. LASER POWER ADJUSTMENT
Check Iop value of the optical pick-up before adjustments. (Refer to 5-8. Recording and Displaying Iop Information.)
Laser power

Connection :

meter

optical pick-up objective lens Digital volt meter

BD board CN105 pin 1 (I+3V) CN105 pin 2 (Iop)

Adjusting Procedure : 1. Set the laser power meter on the objective lens of the optical pick-up. Connect the digital volt meter to CN105 pin 1 (I+3V) and CN105 pin 2 (Iop). 2. Rotate the AMS knob and display �LDPWR ADJUST� (C13). (Laser power : For adjustment) 3. Press the @/1 button once and display �LD 0.9 mW $ �. 4. Rotate the AMS knob so that the reading of the laser power meter becomes 0.85 to 0.91 mW. Press the @/1 button after setting the range knob of the laser power meter, and save the adjustment results. (�LD SAVE $ � will be displayed for a moment.) 5. Then �LD 7.0 mW $ � will be displayed. 6. Rotate the AMS knob so that the reading of the laser power meter becomes 6.9 to 7.1 mW, press the @/1 button and save it. Note : Do not perform the emission with 7.0 mW more than 15 seconds continuously.

30

You might also want to buy

$4.99

MDSPC3 SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.76 - Number of Queries: 102 - Query Time: 0.339