CX-683
- Removing the Carriage Motor (2/2)
1. Remove the screw, then remove the Holder. 2. Remove the screw, remove the flat spring situated in the position indicated by the black arrow head, then drive out the Carriage Motor through the direction indicated by the white arrow head.
- Removing the Spindle Motor (2/2)
1. Peel off solder provided in the circled position, then remove the lead wire. 2. Remove the three screws, then drive out the Spindle Motor through the direction indicated by the white arrow head. Note: When the PU Unit is installed, it must be moved along the outer perimeter.
- Removing the Loading Motor (2/2)
1. Peel off solder in the circled position, then remove the Flexible PCB.
2. Remove the four screws, then dismount the Bracket. 3. Remove the two screws, then dismount the Motor Bracket. 4. Remove the two screws, then dismount the Loading Motor. When replacement of the Loading Motor is complete, apply 7V to the new Loading Motor with the chassis being assembled (without the MD Unit, though). Then, insert the disk and clamp.
- Why clamping is required