Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
 ;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
 ;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
 ;
Manual was just as described!!! I odered it and in less than a day was able to download it and the text was clear and pages were all complete just as the original manual was. Purcashed this for a friend and they were more than happy. Perfect all around!
 ;
Excellent service and prompt delivery. But it's not a manual - only 4 pages wiring diagrams.
Thanks.
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
Adjustment Location: [BD BOARD] (Conductor Side)
level : 1.45 ± 0.3Vp-p
E-F Balance (1 Track jump) Check
oscilloscope BD board TP(TEO) TP(VC)
12 TP (TEO)
TP (AGCCON) IC103 1 24 40 41 TP (FEI)
TP (XPCK) 21 20 1 80 60 61
Procedure : 1. Connect oscilloscope to TP (TEO) and TP (VC). 2. Turned Power switch on. 3. Load a disc (YEDS-18) and playback the number five track. 4. Press the gG button. (Becomes the 1 track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform center of waveform B 0V level=1.3±0.6Vp-p Specified level: �� � 100=less than ±22% A B symmetry A (DC voltage)
TP (FEO) TP (VC)
IC101
TP (RF)
TP (DGND)
6. After check, remove the lead wire connected in step 1. RF PLL Free-run Frequency Check Procedure : 1. Connect frequency counter to test point (XPCK) with lead wire.
BD board TP (XPCK) frequency counter
2. Turned Power switch on. 3. Put the disc (YEDS-18) in to play the number five track. Confirm that reading on frequency counter is 4.3218MHz.