Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I had been looking for a Manual for my CS2150 for quite a while -- in fact I had just about given up. I saw this site and decided to download the Manual. When I Received it by Email I was really pleased with what I got, with the result that My Kenwood 'Scope is now 100% repaired and working well. As an AV Serviceman, you need a good 'scope, and thanks to this site, and the Service Manual, I have been able to repair it. The Manual was a copy of the Factory Original and the copy was very clear, especially in the area of the Circuit Schematics, where You really need to be sure of what You are looking at.
 ;
I recently purchased a manual for a Samsung DLP tv to help with a trouble shooting problem I was having. Every tv repair shop wanted close to $400.00 for the fix, but after I found Owner-Manuals.com I hit pay dirt. The manual they had for me to purchase and download was a complete service manual for the exact tv I needed. It was complete with wiring diagrams, schematics, and even part numbers. If your the fix it yourself type I highly recommend trying to find any manual here before paying someone else to fix whatever problem your having.
 ;
Once again, excellent price and manual delivered in a timely manner and as advertised!
 ;
Outstanding quality manual. This is the exact documentation I needed to service my AKAI GX-210D. This is a PERFECT COPY of the service manual for my machine. Outstanding service. Thank-you!
 ;
This service manual have great value... Recommended A+++++++
HCD-GX355/GX555/RG270/RG475/RG575 SECTION 4 TEST MODE
MC COLD RESET
The cold reset clears all data including preset data stored in the RAM to initial conditions. Execute this mode when returning the set to the customer. Procedure: 1. Press three buttons of x , [ILLUMINATION] and [DISC 1] simultane-ously. 2. The message �COLD RESET� is displayed on the fluorescent indicator tube momentarily, then becomes standby states.
AMP TEST MODE
This mode is used to display the parameter of amplifier IC and display the VACS status. Procedure: 1. Press the I/1 button to turn the power on. 2. Press three buttons of x , [ILLUMINATION] and [PRESET EQ] simultaneously. 3. When the AMP test mode is activated, the message �AMP TEST IN� is displayed on the fluorescent indicator tube momentarily, then amplifier adjustment mode is displayed on the fluorescent indicator tube. 4. Press the [DISPLAY] button to changed over between VACS status display mode and the amplifier IC parameter display mode. 5. In this mode, press the [GROOVE] button to changed over DBFB on/off, and �DBFB ON� or �DBFB OFF� is displayed on the fluorescent indicator tube. 6. In this mode, press the [SURROUND] button to changed over surround on/off, and �SURROUND ON� or �SURROUND OFF� is displayed on the fluorescent indicator tube. 7. In this mode, press the [EQ BAND] button to enter the equalizer adjustment mode. In the equalizer adjustment mode, press the [EQ BAND] button to change over the adjustment band as LOW/MID/HIGH. And turn the [l --- EQ + L] knob to adjust the equalizer level of each bands. 8. To release the amplifier IC parameter display mode or equalizer adjustment mode, press the I/1 button to the power off.
AM TUNING INTERVAL CHANGE-OVER (Except AEP, UK, East European, Russian models)
A step of AM tuning interval can be changed over between 9 kHz and 10 kHz. Procedure: 1. Press the I/1 button to turn the power on. 2. Press the [TUNER/BAND] button to select �AM�. 3. Press the I/1 button to turn the power off. 4. Press two buttons of [PLAY MODE/TUNING MODE] and I/1 simultaneously. 5. The message �AM 9K STEP� or �AM 10K STEP� is displayed on the fluorescent indicator tube, and thus the channel step is changed over.
CD SHIP (LOCK) MODE
This mode moves the optical pick-up to the position durable to vibration. Use this mode when returning the set to the customer after repair. Procedure: 1. Press the I/1 button to turn the power on. 2. Press the [CD] button to select �CD�. 3. Press two buttons of [CD] and [POWER] simultaneously. 4. The message �LOCK� is displayed on the fluorescent indicator tube, and the CD ship mode is set.
CD SHIP (LOCK) MODE & COLD RESET
This mode is used to perform CD chip (lock) mode and cold reset simultaneously. Procedure: 1. Press the I/1 button to turn the power on. 2. Press the [CD] button to select �CD�. 3. Press three buttons of x , [CD] and [DISPLAY] simultaneously. 4. The message �COLD RESET� is displayed on the fluorescent indicator tube momentarily, then becomes standby states.
CD TRAY LOCK MODE
This mode is used to unable to take sample disc out of tray in the shop. Procedure: 1. Press the I/1 button to turn the power on. 2. Press the [CD] button to select �CD�. 3. Load a disc and press two buttons of x and Z for 5 seconds. 4. The message �LOCKED� is displayed on the fluorescent indicator tube and the CD tray is locked. (Even if pressing the Z button, the message �LOCKED� is displayed on the fluorescent indicator tube and the CD tray is locked) 5. To release this mode, press two buttons of x and Z for 5 seconds. 6. The message �UNLOCKED� is displayed on the fluorescent indicator tube and the CD tray is unlocked.