Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Some years back I pruchased a Sansui G-9000. I had it cleaned up and a problem with the left channel repaired. When I got it back I hooked it up to my tape decks, turn tables, TV and it played great. The only thing I was not really satisfied with was the performance of my Graphic Equalizer. I purchased this owner's manual had poured myself a cup of coffee. The manual is well organized and written in plain language. It also contained the solution to my dissatisfaction. By using the preamp connections coupled I was able to run everything through my graphic equalizer and now enjoy the full potential of my complete system.
 ;
An excellent service for the price, however, it would also have been handy if the troubleshooter pages were included. The manual is only sent in the language of your country, thus it looks as though there are some pages missing. Otherwise highly recommended.
 ;
I am happy to get a rare TECHNICS SH-9090 Owner's Manual by PDF in clear copy.
 ;
Hr, klasse , good manual, verry fast on my e-mail, very usefull manual. rgds; ahm zeegers
 ;
I received the owners manual complete download. Wow did it help me. So glad for your website. Can you include an ownersmanual for people lol!
Thanks, sure I will be back
HCD-DX30/RG40
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
Adjustment Location: [BD BOARD] (Conductor Side)
level : 1.45 ± 0.3Vp-p
E-F Balance (1 Track jump) Check
oscilloscope BD board TP(TEO) TP(VC)
12 TP (TEO)
TP (AGCCON) IC103 1 24 40 41 TP (FEI)
TP (XPCK) 21 20 1 80 60 61
Procedure : 1. Connect oscilloscope to TP (TEO) and TP (VC). 2. Turned Power switch on. 3. Load a disc (YEDS-18) and playback the number five track. 4. Press the gG button. (Becomes the 1 track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform center of waveform B 0V level=1.3±0.6Vp-p Specified level: �� � 100=less than ±22% A B symmetry A (DC voltage)
TP (FEO) TP (VC)
IC101
TP (RF)
TP (DGND)
6. After check, remove the lead wire connected in step 1. RF PLL Free-run Frequency Check Procedure : 1. Connect frequency counter to test point (XPCK) with lead wire.
BD board TP (XPCK) frequency counter
2. Turned Power switch on. 3. Put the disc (YEDS-18) in to play the number five track. Confirm that reading on frequency counter is 4.3218MHz.