Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
I do not have very much to say.
The price is quite covenient, delivery was better as promised (about 12 ours, against the specified 24 hours if I remember well), and the quality of the PDF is more than acceptable.
The Service Manual of Sansui R30 itself is also satisfactory: good graphic for schematics and layouts, simple and well structured.
Giovanni Bianchi
 ;
Happy to find finally a schematic for this amplifier. The schematic is of good quality, the pcb layout is useless: all is black. Never the less, it is very easy to find the components on the board using the schematics.
 ;
Hard to find manual was ready the next day. Scans were very legible (including schematics). All the essential parts of the service manual were present (adjustment procedure, schematics, and parts list). It would have been nice if the rest of the manual was included (disassembly procedure, theory of operation, etc.).
 ;
The Service Manual for the Kenwood KR-V55R provided by owner-manuals.com was as described/advertised. The contents provided the necessary information to effect a diagnosis of the unit. The schematics above all else was instrumental in tracing the the signal flow from component to component.
 ;
This manual was the factory original. Excellent value and contained all the details I needed. Easy dowwnload provided the information when I needed it.
HCD-DX10/RG4SR/RG20/RG30T
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. RF Level Check
oscilloscope CD board IC751 pin q; GND
Procedure : 1. Connect oscilloscope to pin q; (IC751). 2. Turned Power switch on. 3. Load a disc (YEDS-18) and playback. 4. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not.
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
level : 1.4 to 2.1 Vp-p
Adjustment Location: CD board [CD BOARD] (Component Side)
CN732
CN731 TP connected to pin q; (IC751) C746A
CN733
14
|
|
 |
> |
|
|