Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
Text excerpt from page 20 (click to view)
HCD-DX30/RG40
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
Procedure : 1. Connect oscilloscope to TP (TEO) and TP (VC). 2. Turned Power switch on. 3. Load a disc (YEDS-18) and playback the number five track. 4. Press the gG button. (Becomes the 1 track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform center of waveform B 0V level=1.3±0.6Vp-p Specified level: �� � 100=less than ±22% A B symmetry A (DC voltage)
TP (FEO) TP (VC)
IC101
TP (RF)
TP (DGND)
6. After check, remove the lead wire connected in step 1. RF PLL Free-run Frequency Check Procedure : 1. Connect frequency counter to test point (XPCK) with lead wire.
BD board TP (XPCK) frequency counter
2. Turned Power switch on. 3. Put the disc (YEDS-18) in to play the number five track. Confirm that reading on frequency counter is 4.3218MHz.