Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I expect a wonderful result as alaways!!!!!!
Usually is much faster....
 ;
Wow very wonderful and clear!!!! I will always trust them
 ;
Providing the manual works fine, quickly and without any problems for an acceptable price. After printing the service manual it took me only a short time to repair my carradio from Clarion. Thank You! Greetings from Heiko
 ;
I was searching a way to modify the original phono-in entry (for connection of vynil disc player, with RIAA equalization) to a line-in entry (for connection of modern analog entries, eg. ipod, mp3player).
This service manual gave me the correct hints.
It contains very useful infos for repairing and modifing the hi-fi, such as disassembling instructions, block diagrams, schematic diagrams, PCB prints, replacement parts list.
Very good!
 ;
Great Job!!! clear and efficient as always!!
it is really nice to have peple that are doing such a good work!!!!!
CDP-S3 SECTION 5 ELECTRICAL ADJUSTMENTS
Note :
E-F Balance (1 Track jump) Check
oscilloscope BD board TP(TEO) TP(DVC)
1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use LUV-P01 (4-999-032-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. S-Curve Check
BD board TP(FEO) TP(DVC) Oscilloscope
Procedure : 1. Connect an oscilloscope to TP (TEO) and TP (DVC). 2. Turn Power switch on. 3. Load a disc (LUV-P01) and playback the number nine track. 4. Press the N button. (Becomes the 1 track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform center of waveform B DVC level=1.0 ±0.5Vp-p symmetry A (DC voltage)
Procedure : 1. Connect an oscilloscope to TP (FEO). 2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead wire. 3. Turn Power switch on. 4. Load a disc (LUV-P01) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 5. Confirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 2 ± 0.5 Vp-p.
S-curve waveform symmetry
6. Adjust RV101 on the BD board so that the center of waveform becomes the same voltage of DVC. (i.e. A=0V) Adjustment Location: [BD BOARD] (Conductor Side)
A within 2 ±0.5Vp-p B
6. After check, remove the lead wire connected in step 2.
Note : � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
RF Level Check
BD board TP(RFDC) TP(RFAC) TP(DVC) oscilloscope
TP (DVC) TP (RFAC) 15 1 IC103 16 30 TP (FEO) TP (TEO) 40 41 TP (RFDC)
21 20
TP (FEI)
IC101 60 61
1 80
Procedure : 1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP (RFAC). 2. Turn Power switch on. 3. Load a disc (LUV-P01) and playback. 4. Confirm that oscilloscope waveform is clear and check if RF signal level is correct or not.
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RV101
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
level : 0.65 ±0.15Vp-p (RFDC) 1.1 ±0.4Vp-p (RFAC)
11
|
|
 |
> |
|