Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> PIONEER >> MJ-NS1/ZPWXJ Service Manual
 
 0 item(s) in your cart 

PIONEER MJ-NS1/ZPWXJ
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PIONEER MJ-NS1/ZPWXJ Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 PMC100 PHILIPS Service Manual by Nils Thei;
High quality scan of service manual. I am satisfied!
 ATA301/L AKAI Service Manual by Jorn Peder Wind;
Excellent copies. I will use "Owner Manual" again a second time.
 SLD303/K TECHNICS Service Manual by Stefano Erdini;
Very good manual for Technics SL 303. Manuale molto utile.
 AWE600E PANASONIC Service Manual by Johannes Zündel;
About one hour after checkout, the manual was available for download. Clear reading and detailed. Thanks
 RM-C950 SONY Service Manual by Johannes Zündel;
Excellent transaction - clean document received - Thanks a lot

Text excerpt from page 31 (click to view)
MJ-NS1

6.1.3 MD Mechanism Assy Adjustment and Check 1 Temperature Check (Please perform this check soon after the power has been switched on.)
Note: When IC101 (RF-AMP) or IC104 (mechanical controller) has been exchanged or when a correction changing VD+3 has been made, be sure to correctly perform all steps up to step 7.

Step No.
1 2 3

Operation Keys and Operation Method
In the Power ON state, selecting MD function,short the "MECHA TEST pin". Press the ¶ (REC) key. When && is 80 or more at this time, the adjustment is OK (step 4 and following can be omitted.)

FL Display
EJECT TEMP??&& Test mode

Status

Remarks

The microcomputer starts measuring ??: Measuring value End &&: Set value 80 is the default value (unadjusted). TEMP

When && is 80 (not passed) Measure the ambient temperature T (°C) and check that the measuring value (??) is within the standard in regard to the microcomputer set value (&&). 4 Note: When the indication of the measuring value (??) is not stable, and the ambient temperature T (°C) is 25 °C or less, set to the lower value. When the ambient temperature is over 25 °C, set to the higher value.

TEMP??80

µ-com Measuring value Room Temperature [T (°C)] 11.6 to 16.9 17.0 to 22.3 22.4 to 27.6 27.7 to 33.0 33.1 to 38.4

µ-com Set value hex= (?? � &&)

Measuring value (??) �2 Measuring value (??) �1 Measuring value (??) Measuring value (??) +1 Measuring value (??) +2

When the microcomputer value is

79 7A 7B 7C 7D

� +

5 6

Change && with the + key and � key. Turn off the power of the CD tuner.

TEMP 7B 7B Data writes to the EEPROM and turns the system power to off. Test mode returns to the normal mode.

2 Laser Power Check
Step No.
1 2 3

Operation Keys and Operation Method
In the Power ON state, selecting MD function,short the "MECHA TEST pin". Press the SET key (Remote control unit). Measure the laser power with an optical power meter.

FL Display EJECT Test mode ppw ppw

Status

Remarks
Laser wavelength: 780 nm

PLAY power output status

TEMP At this time, check that the measuring value (PLAY power) meets the standard value of the table on the right. 4 Note: When the standard value on the right is applied, the numerical value immediately after entry into test mode 2 shall be taken as the standard. ppw µ-com Measuring value hex=(?? � &&) +02 to +04 �01 to +01 �02 to �04 5 Press the SET key. At this time, check that the measuring value (REC power) meets the standard value of the table on the right. rpw µ-com Set value Standard value (mW) 0.69 ± 0.12 0.67 ± 0.1 0.63 ± 0.1 May be omitted.

REC power output status hex=(?? � &&) Standard value (mW) 6.18 ± 0.93 5.79 ± 0.87 5.47 ± 0.82

6

rpw

+02 to +04 �01 to +01 �02 to �04 The LD goes out.

7

Press the 7 (STOP) key.

31

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

MECABLITZ 60 CT4 METZ
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.222 - Number of Queries: 121 - Query Time: 0.053