Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
I was very glad recieving the service manal from You. Additionaly very fast. Extremaly nice servicing. Thanks very mach! Now my GX-220 working better, than it was made. Alexander from Moscow, Russia/
 ;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
 ;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
 ;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
5. To shift the CTL waveform, press [CH UP] or [CH DOWN] buttons on the unit. Then make sure that the maximum output position of PB FM envelope signal becomes within ±2ms from preset position.
5. When Guide Rollers [2] and [3] (Refer to Fig. M3) are aligned properly, there is no envelope drop either at the beginning or end of track as shown in Fig. M9.
Good
FM envelope signal 2ms Center Position
Dropping envelope level at the beginning of track.
Fig. M8
FM envelope output signal is adjusted at maximum. CTL signal
No Good
Dropping envelope level at the end of track.
FM envelope output signal is low.
Fig. M7
6. Set the Tracking Control Circuit to the preset position by pressing [CH UP] button on the unit and then [PLAY] button on the unit.
Fig. M9
1-C. Checking/Adjustment of Envelope Waveform
Purpose: To achieve a satisfactory picture, adjust the Guide Rollers so that the PB FM envelope becomes as flat as possible. Symptom of Misalignment: If the envelope output is poor, noise will appear in the picture. The tracking will then lose precision and the playback picture will be distorted by any slight variation of the Tracking Control Circuit. 1. Connect the oscilloscope to TP (C-PB) on the Main CBA. Use TP (RF-SW) as a trigger. 2. Playback the Gray Scale on the Alignment Tape (FL8NW). Set the Tracking Control Circuit to the preset position by pressing [CH UP] button on the unit and then [PLAY] button on the unit. Adjust the height of Guide Rollers [2] and [3] (Fig. M3, Page 2-3-3) watching the oscilloscope display so that the envelope becomes as flat as possible. To do this adjustment, turn the top of the Guide Roller with the Guide Roller Adj. Screwdriver. 3. If the envelope is as shown in Fig. M7, adjust the height of Guide Roller [2] (Refer to Fig. M3) so that the waveform looks like the one shown in Fig. M9. 4. If the envelope is as shown in Fig. M8, adjust the height of Guide Roller [3] (Refer to Fig. M3) so that the waveform looks like the one shown in Fig. M9.
Envelope is adjusted properly. (No envelope drop)
Fig. M10
Note: Upon completion of the adjustment of Guide Rollers [2] and [3] (Refer to Fig. M3), check the X Value by pushing the [CH UP] or [CH DOWN] buttons on the unit alternately, to check the symmetry of the envelope. Check the number of pushes to ensure preset position. The number of pushes of the [CH UP] button to achieve 1/2 level of envelope should match the number of pushes of the [CH DOWN] button from center. If required, redo the �X Value Alignment.�
2-3-4
N2461FLMA
|
|
 |
> |
|