Text excerpt from page 62 (click to view)
Precautions
5.22 MP Pick-up Ass�y
1. Before you remove the MP Pick-up Ass�y, you should remove: - MPF Ass�y (Refer to the 5.3) - Main Drive Ass�y (Refer to the 5.7) - Top Cover (Refer to the 5.13) - Inner Cover (Refer to the 5.15) 4. Pull and remove the lock equipment, then rotate the Bearing as shown below.
Bearing
2. First of all remove two screws. Lift up the MP Pick-up Shaft for taking out the MP Pick-up Rack.
Rack
MP Pick Up Rack
5. Slide the cam to the left by pulling on the MP Pick-up shaft
Cam MP Pick Up Shaft
3. Remove the E-Rings on both ends of Gear Ass�y and remove Ass�y as shown below.
E-Ring