Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the original manufacturers service manual, with detailed info on the circit boards, explosion drawings of all parts in assembly order, and tuning instructions. The only thing missing is the information on the dimensions of the various drive belts. mail me if you need them. gcrossman_at_aol.com
 ;
Ordered service manuel for a hard to find plasma tv - your company made it easy to find and purchase - I will use you again
Thanks for your help
 ;
This is a high quality manual with clear schematic and components layout diagrams ; with service procedure included.
 ;
This service manual for the Kenwood KT-990D was reproduced really well ,is very legible and manual is complete.Combined with the low price paid,in the future,I will be checking Owner-Manuals.com any time I need a manual.
 ;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
ELECTRICAL ADJUSTMENTS
2-6: WHITE BALANCE
CH-2
NOTE: Adjust after performing CUT OFF adjustment. 1. Place the set with Aging Test for more than 15 minutes. 2. Receive the color bar pattern. 3. Using the remote control, set the brightness and contrast to normal position. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (10) on the remote control to select "R CUT OFF". 5. Using the VOL. UP/DOWN button on the remote control, adjust the R CUT OFF. 6. Press the CH. UP/DOWN button on the remote control to select the "R DRIVE", "B DRIVE", "G CUT OFF" or "B CUT OFF". 7. Using the VOL. UP/DOWN button on the remote control, adjust the R DRIVE, B DRIVE, G CUT OFF or B CUT OFF. 8. Perform the above adjustments 6 and 7 until the white color is looked like a white. 2-7: FOCUS 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Turn the Focus Volume fully counterclockwise once. 4. Adjust the Focus Volume until picture is distinct. 2-8: HORIZONTAL PHASE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (05) on the remote control to select "H PHAS". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-9: VERTICAL SHIFT 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (07) on the remote control to select "V SFT". 4. Check if the step No. V. SHIFT is "03". 5. Adjust the VR401 until the horizontal line becomes fit to the notch of the shadow mask.
CH-1 6.5H
Fig. 2-1-B 2-2: VCO FREERUN 1. Receive the VHF HIGH (63dB). 2. Place the set with Aging Test for more than 10 minutes. 3. Connect the digital voltmeter between the pin 5 of CP351 and the pin 1 (GND) of CP351. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (03) on the remote control to select "V.VCO". 5. Press the VOL. UP/DOWN button on the remote control until the digital voltmeter is 2.5V. 6. After the 2.5V adjustment, countdown the VIF VCO step No. by 1 step with the VOL. DOWN button. 2-3: RF AGC 1. Receive the VHF HIGH (63 ± 1dB). 2. Connect the digital voltmeter between the pin 5 of CP351 and the pin 1 (GND) of CP351. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (02) on the remote control to select "RF AGC". 4. Press the VOL. UP/DOWN button on the remote control until the digital voltmeter is 2.7 ± 0.05V.
(TV SECTION)
2-4: CONSTANT VOLTAGE 1. Using the remote control, set the brightness and contrast to normal position. 2. Connect the digital voltmeter to TP601 (R520). 3. Set condition is AV MODE without signal. 4. Adjust the VR502 until the digital voltage is 135 ± 0.5V. 2-5: CUT OFF 1. Adjust the unit to the following settings. R CUT OFF=127, G CUT OFF=127, B CUT OFF=127, SUB BRI.CENT=127, SUB CONT.MAX=100 2. Place the set with Aging Test for more than 15 minutes. 3. Set condition is AV MODE without signal. 4. Using the remote control, set the brightness and contrast to normal position. 5. Activate the adjustment mode display of Fig. 1-1 and press the channel button (01) on the remote control to select "CUT OFF". 6. Adjust the Screen Volume until a dim raster is obtained.
D3-2
|
|
 |
> |
|