Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
 ;
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
 ;
Complete manual including mechanical part in good pdf quality. Shaded greys of the pcb due to pdf not perfect but usable.
 ;
Nice pdf file of the manual sent promptly. Thanks.
 ;
Complete MFG Service Manual at a good price FAST !
ELECTRICAL ADJUSTMENTS
2-3: RF AGC 1. Receive the VHF HIGH (63dB). 2. Connect the digital voltmeter between the pin 5 of CP351 and the pin 1 (GND) of CP351. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (02) on the remote control to select "RF AGC DELAY". 4. Press the VOL. UP/DOWN button on the remote control until the digital voltmeter is 2.9 ± 0.5V.. 2-8: HORIZONTAL PHASE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (05) on the remote control to select "H PHASE". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-9: VERTICAL SHIFT 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (07) on the remote control to select "V SHIFT". 4. Check if the step No. V. SHIFT is "3". 5. Adjust the VR401 until the horizontal line becomes fit to the notch of the shadow mask. 2-10: VERTICAL SIZE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (06) on the remote control to select "V SIZE". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on upside and downside becomes minimum. 2-11: SUB BRIGHTNESS 1. Receive the monoscope pattern. (RF Input) 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (13) on the remote control to select "BRIGHTNESS". 4. Press the VOL. UP/DOWN button on the remote control until the white 10% is starting to be visible 5. Receive the monoscope pattern. (Audio Video Input) 6. Press the INPUT SELECT button on the remote control to set to the AV mode. Then perform the above adjustments 2~4. 2-12: SUB CONTRAST 1. Activate the adjustment mode display of Fig. 1-1 and press the channel button (14) on the remote control to select "CONTRAST". 2. Press the VOL. UP/DOWN button on the remote control until the contrast step No. becomes "100" 3. Press the INPUT SELECT button on the remote control to set to the AV mode. Then perform the above adjustments 1~2.
(TV SECTION)
2-4: CONSTANT VOLTAGE 1. Connect the digital voltmeter to the TP601. 2. Set condition is AV MODE without signal. 3. Using the remote control, set the brightness and contrast to normal position. 4. Adjust the VR502 until the digital voltmeter is 135 ± 0.5V. 2-5: CUT OFF 1. Adjust the unit to the following settings. R CUT OFF=128, G CUT OFF=128, B CUT OFF=128, BRIGHTNESS=128, CONTRAST=100 2. Place the set with Aging Test for more than 15 minutes. 3. Set condition is AV MODE without signal. 4. Using the remote control, set the brightness and contrast to normal position. 5. Activate the adjustment mode display of Fig. 1-1 and press the channel button (01) on the remote control to select "CUT OFF". 6. Adjust the Screen Volume until a dim raster is obtained. 2-6: WHITE BALANCE NOTE: Adjust after performing CUT OFF adjustment. 1. Place the set with Aging Test for more than 15 minutes. 2. Receive the gray scale pattern from the Pattern Generator. 3. Using the remote control, set the brightness and contrast to normal position. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (10) on the remote control to select "R CUT OFF". 5. Press the CH. UP/DOWN button on the remote control to select the "R CUT OFF", "G CUT OFF", "B CUT OFF", "R DRIVE" or "G DRIVE". 6. Adjust the VOL. UP/DOWN button on the remote control to whiten the R CUT OFF, G CUT OFF, B CUT OFF, R DRIVE, and G DRIVE at each step tone sections equally. 7. Perform the above adjustments 5 and 6 until the white color is looked like a white. 2-7: FOCUS 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Turn the Focus Volume fully counterclockwise once. 4. Adjust the Focus Volume until picture is distinct.