Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It is an very good and clear scanned service manual.
very recommended.
 ;
Easy to order the manual. Good quality and fast delivery.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
ELECTRICAL ADJUSTMENTS
2-10: VERTICAL SIZE 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (06) on the remote control to select "V SIZE". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on upside and downside becomes 10 ± 2%. 2-11: SUB BRIGHTNESS 1. Receive the monoscope pattern. (RF Input) 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (13) on the remote control to select "BRI.CENT". 4. Press the VOL. UP/DOWN button on the remote control until the white 10% is starting to be visible. 5. Receive the monoscope pattern. (Audio Video Input) 6. Press the INPUT SELECT button on the remote control to set to the AV mode. Then perform the above adjustments 2~4. 2-12: SUB CONTRAST MAX 1. Activate the adjustment mode display of Fig. 1-1 and press the channel button (17) on the remote control to select "CONT.MAX". 2. Press the VOL. UP/DOWN button on the remote control until the contrast step No. becomes "100". 3. Receive a broadcast and check if the picture is normal. 4. Press the INPUT SELECT button on the remote control to set to the AV mode. Then perform the above adjustments 1~3. 2-13: SUB TINT 1. Receive the color bar pattern. (RF Input) 2. Using the remote control, set the brightness, contrast, color and tint to normal position. 3. Connect the oscilloscope to TP801. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (22) on the remote control to select "TINT". 5. Press the VOL. UP/DOWN button on the remote control until the section "A" becomes a straight line. (Refer to Fig. 2-2) 6. Receive the color bar pattern. (Audio Video Input) 7. Press the INPUT SELECT button on the remote control to set to the AV mode. Then perform the above adjustments 2~5. 100% 2-14: SUB COLOR 1. Receive the color bar pattern. (RF Input) 2. Using the remote control, set the brightness, contrast, color and tint to normal position. 3. Connect the oscilloscope to TP803. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (19) on the remote control to select "COL.CENT". 5. Adjust the VOLTS RANGE VARIABLE knob of the oscilloscope until the range between white 100% and 0% is set to 4 scales on the screen of the oscilloscope. 6. Press the VOL. UP/DOWN button on the remote control until the red color level is adjusted to 110 ± 10% of the white level. (Refer to Fig. 2-3) 7. Receive the color bar pattern. (Audio Video Input) 8. Press the INPUT SELECT button on the remote control to set to the AV mode. Then perform the above adjustments 2~6. White 0%
"A"
Fig. 2-2
Red Level White 100%
Fig. 2-3
D3-3
|
|
 |
> |
|