|
Who's Online
There currently are 5656 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Thanks God for the internet and thanks for the service like this - proffessional solution on time.
;
About the service it's very fast and reliable. About the manual the quality is high enough to read even the tiniest details on the wiring diagrams so you can't ask much more than that, let it alone for a manual of a product from 20 years ago. Thank you, very satisfied.
;
The downloaded quality was as good as the orignial
;
This is a great and complete Service Manual for the Sharp GF8585HB. Giving full and detailed technical insight. Good to find these manuals online.
;
Everything was ok with the manual. If I have a small complaint, is that I ordered it during the weekend and I think you guys were closed. But I did receive it late Sunday. I will surely order from you again
ELECTRICAL ADJUSTMENTS
2-2: RF AGC 1. Place the set with Aging Test for more than 15 minutes. 2. Receive the VHF HIGH (63dB). 3. Connect the digital voltmeter between the pin 5 of CP601 and the pin 1 (GND) of CP601. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (02) on the remote control to select "RF.AGC". 5. Press the VOL. UP/DOWN button on the remote control until the digital voltmeter is 2.5 ± 0.05V. 2-3: SEPARATION Please do the method (1) or method (2) adjustment. Method (1) 1. Set the multi-sound signal generator for each different L-ch and R-ch frequency (Ex. L-ch=2KHz, R-ch=400Hz) and receive the RF signal. 2. Connect the oscilloscope to the Audio Out Jack. 3. Press the AUDIO SELECT button on the remote control to set to the stereo mode. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (35) on the remote control to select �FM LVL�. 5. Press the VOL. UP/DOWN button on the remote control to adjust it until the audio output wave becomes a fine sine wave. Method (2) 1. Set the multi-sound signal generator L-ch=1KHz, R-ch =Non input and receive the RF signal. 2. Connect the oscilloscope to the Audio Out Jack (R-ch). 3. Press the AUDIO SELECT button on the remote control to set to the stereo mode. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (35) on the remote control to select �FM LVL�. 5. Press the VOL. UP/DOWN button on the remote control to adjust it until the R-ch output becomes minimum. 6. Set the multi-sound signal generator L-ch=Non input, R-ch=1KHz and receive the RF signal. 7. Connect the oscilloscope to the Audio Out Jack (L-ch). 8. Press the AUDIO SELECT button on the remote control to set to the stereo mode. 9. Activate the adjustment mode display of Fig. 1-1 and press the channel button (35) on the remote control to select �FM LVL�. 10.Press the VOL. UP/DOWN button on the remote control to adjust it until the L-ch output becomes minimum. 2-5: CUT OFF 1. Place the set with Aging Test for more than 15 minutes. 2. Set condition is AV MODE without signal. 3. Using the remote control, set the brightness and contrast to normal position. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (01) on the remote control to select "CUT OFF". 5. Adjust the Screen Volume until a dim raster is obtained. 2-6: WHITE BALANCE NOTE: Adjust after performing CUT OFF adjustment. 1. Place the set with Aging Test for more than 15 minutes. 2. Receive the gray scale pattern from the Pattern Generator. 3. Using the remote control, set the brightness and contrast to normal position. 4. Activate the adjustment mode display of Fig. 1-1 and press the channel button (13) on the remote control to select "R.BIAS". 5. Press the CH. UP/DOWN button on the remote control to select the "R.BIAS", "G.BIAS", "B.BIAS", "B.DRV" or "G.DRV". 6. Adjust the VOL. UP/DOWN button on the remote control to whiten the R.BIAS, G.BIAS, B.BIAS, B.DRV, and G.DRV at each step tone sections equally. 7. Perform the above adjustments 5 and 6 until the white color is looked like a white. 2-7: FOCUS 1. Receive the monoscope pattern. 2. Turn the Focus Volume fully counterclockwise once. 3. Adjust the Focus Volume until picture is distinct. 2-8: HORIZONTAL POSITION 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Activate the adjustment mode display of Fig. 1-1 and press the channel button (04) on the remote control to select "H.POSI". 4. Press the VOL. UP/DOWN button on the remote control until the SHIFT quantity of the OVER SCAN on right and left becomes minimum. 2-9: VERTICAL POSITION 1. Receive the monoscope pattern. 2. Using the remote control, set the brightness and contrast to normal position. 3. Adjust the VR404 until the horizontal line becomes fit to the notch of the shadow mask.
(TV SECTION)
2-4: CONSTANT VOLTAGE 1. Set condition is AV MODE without signal. 2. Using the remote control, set the brightness and contrast to normal position. 3. Connect the digital voltmeter to TP401. 4. Adjust the VR1701 until the digital voltmeter is 117 ± 0.5V.
D3-2
|
|
|
> |
|