Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Thanks to this service manual I repaired my old camcorder! The manual perfectly explains how to disassemble the camcorder step by step.
 ;
This manual is very useful because it presents the technical specifications of the cd player, including the manufacturer of the reader, this helps if you need to replace it. It also displays the settings and layout of the circuit.
 ;
Manual was a good representation of service infomation for the EWV404. It worked well for my repair.
 ;
Great quality copy, right what I was looking for, all I need to fix my radio.
Thanks
 ;
I BOUGHT A PAIR OF INFINITY VINTAGE SPEAKERS THAT REQUIRED TO BE REPAIRED AND THE ELECTRONIC TECHNICIAN ASKED ME FOR THE SERVICE MANUAL.
I TRIED TO GET IT AT THE MANUFACTURER'S SITE WITH NO SUCCESS, SO I STARTED TO LOOK FOR IT IN THE WEB FOR A LONG TIME, UNTIL I FOUND THE SERVICE MANUAL IN THIS EXCELLENT SITE "OWNER'S MANUAL.COM".
NOW I HAVE MY SPEAKERS WORKING AND ENJOYING THE MUSIC I LIKE.
THANKS TO "OWNER`S MANUAL.COM" I RECOMMEND THIS SITE TO EVERYONE.
ADJUSTMENT <DECK> (FX-NH2000)
< DECK SECTION >
1. Tape Normal Speed Adjustment Settings : � Test tape : TTA�100 (Tape center) � Test point : TP1 (Rch), TP2 (Lch) � Adjustment location : SFR1 Method : Play back the test tape and adjust SFR1 so that the test point becomes 3000Hz ± 5Hz(FWD) Then check REV speed is 3000Hz ± 45Hz. 2. High Speed Check Settings : � Test tape : TTA�100 (Tape center) � Test point : TP1 (Rch), TP2 (Lch) Method : After normal speed adjustment, play back (High speed) the test tape. Then check tape speed is 6000Hz ±400Hz (FWD). 3. Head Azimuth Adjustment Settings : � Test tape : TTA�300 � Test point : TP1(Rch), TP2 (Lch) � Adjustment location : Head azimuth adjustment screw Method : Play back the 10kHz signal of the test tape and adjust screw so that the output becomes maximum.Next, perform on each FWD PLAY and REV PLAY mode. 4 PB Sensitivity Adjustment (DECK1, DECK2) Settings : � Test tape : TTA�200 � Test point : TP1 (Rch), TP2 (Lch) � Adjustment location : SFR301 (DECK1, Lch) SFR302 (DECK1, Rch) SFR303 (DECK2, Lch) SFR304 (DECK2, Rch) Method : Play back the test tape and adjust SFRs so that the output level of the test point becomes 245mV (DECK2), 260mV (DECK1). 6. REC/PB Sensitivity Adjustment (DECK2) Settings : � Test tape : TTA�602 (NORMAL) � Test point : TP1 (Rch), TP2 (Lch) � Input signal : 1kHz (LINE IN) � Adjustment location : SFR305 (Lch) SFR306 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz signals and adjust SFRs so that the output is 0dB ± 0.5dB. 7. REC/PB Frequency Response Adjustment (DECK2) Settings : � Test tape : TTA�602 (NORMAL) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz / 10kHz (LINE IN) � Adjustment location : SFR351 (Lch) SFR352 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz and 10kHz signals and adjust SFRs so that the output level of the 10kHz signals becomes 0dB ± 0.5dB with respect to that of the 1kHz signal. 8. REC/PB Frequency Response Check (DECK2) Settings : � Test tape : TTA�615 (CrO2) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz signal and check that the output is 0dB ± 2.0dB. 9. REC/PB Sensitivity Check (DECK2) Settings : � Test tape : TTA�615 (CrO2) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz (LINE OUT) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 170mV. Record and play back the 1kHz signal and check that the output is 0dB ± 2.0dB.
5. PB Frequency Response Check (DECK1, DECK2) Settings : � Test tape : TTA�300 � Test point : TP1 (Rch), TP2 (Lch) Method : Play back the 315Hz and 10kHz signals of the test tape and check that the output ratio of the 10kHz signal with respect to that of the 315Hz signal is 0dB . Next, check that the Lch and Rch difference level of 10kHz signal is less than 2dB.