Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
 ;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
 ;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
 ;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
 ;
Very detailed product, also it is a scanning from original, very useful if you have to service this type of amplifier ! Very good product, very hard to find!
ADJUSTMENT <DECK> (FX-NH2000)
< DECK SECTION >
1. Tape Normal Speed Adjustment Settings : � Test tape : TTA�100 (Tape center) � Test point : TP1 (Rch), TP2 (Lch) � Adjustment location : SFR1 Method : Play back the test tape and adjust SFR1 so that the test point becomes 3000Hz ± 5Hz(FWD) Then check REV speed is 3000Hz ± 45Hz. 2. High Speed Check Settings : � Test tape : TTA�100 (Tape center) � Test point : TP1 (Rch), TP2 (Lch) Method : After normal speed adjustment, play back (High speed) the test tape. Then check tape speed is 6000Hz ±400Hz (FWD). 3. Head Azimuth Adjustment Settings : � Test tape : TTA�300 � Test point : TP1(Rch), TP2 (Lch) � Adjustment location : Head azimuth adjustment screw Method : Play back the 10kHz signal of the test tape and adjust screw so that the output becomes maximum.Next, perform on each FWD PLAY and REV PLAY mode. 4 PB Sensitivity Adjustment (DECK1, DECK2) Settings : � Test tape : TTA�200 � Test point : TP1 (Rch), TP2 (Lch) � Adjustment location : SFR301 (DECK1, Lch) SFR302 (DECK1, Rch) SFR303 (DECK2, Lch) SFR304 (DECK2, Rch) Method : Play back the test tape and adjust SFRs so that the output level of the test point becomes 245mV (DECK2), 260mV (DECK1). 6. REC/PB Sensitivity Adjustment (DECK2) Settings : � Test tape : TTA�602 (NORMAL) � Test point : TP1 (Rch), TP2 (Lch) � Input signal : 1kHz (LINE IN) � Adjustment location : SFR305 (Lch) SFR306 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz signals and adjust SFRs so that the output is 0dB ± 0.5dB. 7. REC/PB Frequency Response Adjustment (DECK2) Settings : � Test tape : TTA�602 (NORMAL) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz / 10kHz (LINE IN) � Adjustment location : SFR351 (Lch) SFR352 (Rch) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz and 10kHz signals and adjust SFRs so that the output level of the 10kHz signals becomes 0dB ± 0.5dB with respect to that of the 1kHz signal. 8. REC/PB Frequency Response Check (DECK2) Settings : � Test tape : TTA�615 (CrO2) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 0dB (17mV). Record and play back the 1kHz signal and check that the output is 0dB ± 2.0dB. 9. REC/PB Sensitivity Check (DECK2) Settings : � Test tape : TTA�615 (CrO2) � Test point : TP2 (Lch), TP1 (Rch) � Input signal : 1kHz (LINE OUT) Method : Apply a 1kHz signal and REC mode. Then adjust OSC attenuator so that the output level at the TP1, TP2 becomes 170mV. Record and play back the 1kHz signal and check that the output is 0dB ± 2.0dB.
5. PB Frequency Response Check (DECK1, DECK2) Settings : � Test tape : TTA�300 � Test point : TP1 (Rch), TP2 (Lch) Method : Play back the 315Hz and 10kHz signals of the test tape and check that the output ratio of the 10kHz signal with respect to that of the 315Hz signal is 0dB . Next, check that the Lch and Rch difference level of 10kHz signal is less than 2dB.
� 44 �
|
|
 |
> |
|